Clear-FloTM ICS 400 In-Line Circulating Screen Y Pattern Filters
F415 Head Loss Graph
F420 Head Loss Graph
F430 Head Loss Graph
F440 Head Loss Graph
F460 Head Loss Graph
Note:
To ensure proper circulation, it is important to determine the correct number of open
holes needed.
To determine the number of open holes required, intersect the flow rate with one of the diagonal “holes” line within the grey shaded area on the graph.
e.g. 90 m3/h through a F460 intersects the number 4 diagonal line within the shaded area. This indicates that 4 open holes are needed.
Line marked ‘6’ indicates the pressure loss with 6 holes open.
288
Company policy is one of constant improvement and therefore changes in specifications may be made without notice and without incurring liability. Please refer to www.toro.com.au Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009. Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443