Page 290 - ToroProductCatalogue2016
P. 290

Clear-FloTM SA500C Right Angle Compact Manual Suction Screen Filter
SA500C Dimensional Data
Model Number
Connection (Table Rating)
Screen Area (cm2)
Max. Flow rate (m3/hr)
Flush Flow rate (m3/hr)
D* (mm)
D1* (mm)
H (mm)
H1 (mm)
X (mm)
X1 (mm)
Flush Valve Size (mm)
Operating Weight (kg)
SA502C
FBSP
1010
25
6
150
50
637
174
123
270
15
16
SA503C
FBSP
1678
40
8
150
80
841
189
139
281
20
24
SA540C
Flange (D)
2090
80
10
200
100
933
280
190
343
25
40
1. Maximum flow rate is based on 10 kPa head loss across the filter with clean water. When sizing a filter, filtration load, particulate matter type and size must be considered to de-rating the maximum flow through the filter.
2. Flush flow rate is for an operating pressure of 100 kPa.
Ordering Information
Code
Description
SA502C-80
2" Manual Suction Scanner 80 Mesh MBSP
SA502C-120
2" Manual Suction Scanner 120 Mesh MBSP
SA503C-80
3" Manual Suction Scanner 80 Mesh MBSP
SA503C-120
3" Manual Suction Scanner 120 Mesh MBSP
SA504C-80
4" Manual Suction Scanner 80 Mesh Flanged
SA504C-120
4" Manual Suction Scanner 120 Mesh Flanged
policy is one of constant improvement and therefore changes in specifications may be made without notice and without incurring liability. Please refer to www.toro.com.au Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009. Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443
Application
The SA500C is used in a wide range of applications in the Industrial, Municipal, Commercial and Agricultural sectors. Commonly used as a primary or secondary filter for sprinkler, drip, mini, and micro irrigation systems.
Features
• Filter housing material of construction: Carbon Steel ST37.2
• Pre-treatment: sand blasting up to Sa 2.5 grade
• Exterior & Interior coating: electrostatic oven baked polyester-epoxy powder coating with a thickness of 150-200 micron
• Minimum operating pressure: 100 kPa
• Maximum operating pressure: 1000 kPa
• Maximum working temperature: 65˚C
• Manually operated flush valve
• Manually rotated suction scanner
• Standard 80 mesh (200 micron)
or 120 mesh (120 micron) screen
• Screen made from 316 stainless steel
• Low flush rates, 6-10 m3/h
290
Company
100 90 80 70 60 50 40 30 20 10 0
1 10 100
Flow Rate (m3/hr)
SA500C Pressure Loss Graph
SA503C
SA504C
SA502C
Pressure Loss (kPa)


































































































   288   289   290   291   292