Page 9 - CompressedAir
P. 9

100-200HP MODEL Kobelco KNW Series
                             MULTI-SPEED AIR-COOLED PERFORMANCE DATA

                                                                A0 / EH         A1 / GH              Units
          Lube Oil Pump Motor                                      2              3                  HP
                                                                 1740            1750                RPM
          Lube Oil Pump Capacity                                 11:01           16.2                GPM
          Lube Oil Sump Capacity                                  5.5             9                  GAL
          Discharge Safety Valve               Setting            165             165                PSIG
          Maximum Cooling Duct                Suction             0.12           0.12               IN. W.C.
                                               Outlet             0.12           0.12               IN. W.C.
          Approximate Shipping Weight                            5000            8640                LBS
          Dimensions                          (L x W x H)    79.71 x 48 x 98.64                      IN.
                                                                              104.5 x 70.75 x
                                              (L x W x H)                                            IN.
                                                                                  100
          Discharge Air Connection                               5000            8640                LBS
          Condensate Drain (Qty. 2)          Connection           1/2             1/2               IN. NPT
          Minimum Recommended Air Receiver Size                   53              87                 FT 3
                                                                  400             650                GAL
          Approach Temperature                                    19              20                  °F
          Maximum Ambient Temp.                                   104             104                 °F
          Standard Operating Conditions
          Ambient Pressure                                        14.5           14.5                PSIA
          Ambient Temperature                                     80              80                  °F
          Capacity                                                ± 4             ± 4                 %
          Specific Power                                          ± 5             ± 5                 %
          Relative Hmidity                                        60              60                  %
          Electrical Data                                       A0 / EH         A1 / GH              Units
          Running Amps                                          FLA 110         FLA 216             AMPS
          Recommended Breaker                                     200             400               AMPS
          Starter Type                                         WYE - DELTA     WYE - DELTA
          Voltage                                              460V / 3PH      460V / 3PH
   4   5   6   7   8   9   10   11   12   13   14