Page 2 - Pressure Transient
P. 2

91.8

         Pressure Transient                                       Logger Features


                                                                                   Standard data logging – 1 sample per
          Data Logger                                             Frequency        second to 1 sample per day. Fast
                                                                                   logging – 1 to 100 samples per second.

                                                                  Logger ID        Up to 8 alphanumeric characters
         Sensor Input options
                                                                  Clock            On board 24 hour real time clock with
                                                                                   date facility.
         Analogue         Internal or External Pressure Transducer.   Dimensions   199H x 125W x 66D mm
 44.0                     Supplied with quick fit                  Construction     (7.7”H x 4.7”W x 2.8”D)
                          connector. 0-30 bar, accuracy
                          ±0.1%
                                                                                   Die-cast aluminium enclosure
         Memory           4 GB internal flash memory enables        Weight          1.6 Kg (3.5 lb)
                          up to 2 billion readings.
                                                                  Operating Temp   -20 to +70°C (-5 to +160°F)


         Communication                                            Ingress           IP68
                                                                  protection
                          USB 2.0 connection by MIL connector
          USB             for connection to PC or Tablet.                           Lithium-Thionyl Chloride cell
                                                                  Power             operational for 1 to 5 years depending
                          GPRS to HWM Datagate or customer’s                        on usage External power input (+12V
                          own server, multiple connections per                      or HWM battery box). Battery boxes to
                          day                                                       support more frequent dial-in and long
                                                                                    term accelerated logging
         Internal cellular  Quad band GPRS modem supplying
         modem            850/900/1800/1900MHz bands                                Minimum or maximum duration-
                                                                   Alarms           triggered threshold alarm per
                          GPRS can send data down to every 5                        channel. 16 Alarms per logger. Each
                          mins, with appropriate external                           alarm out comment field 16
                          power source (eg battery pack)                            characters User definable threshold
                                                                                    transient alarm. User selected window
                          USB 2.0 connection by MIL                                 of data around transient transmitted
                          connector for connection to PC                            with alarm
                          or Tablet.






















                                                                 HWM Water Limited
                                                                 Ty Coch House
                                                                 Llantarnam Park Way
                                                                 Cwmbran
                                                                 NP44 3AW
                                                                 United Kingdom
                                                                 Tel:   +44 (0) 1633 489 479
                                                                 Fax:   +44 (0) 1633 877 857
         All Images, text and designs are protected by international and UK copy write law,
         and remain the property of HWM. It is against the law to copy or use any of the   Email:  sales@hwm-water.com
         content from HWM website or literature without the written consent of HWM.   Web:      www.hwmglobal.com
         HWM Ltd. reserve the right to vary the specification.  Issue 1. 06:2017
         MONI T O R IN G  ASS ET S ,   DEL I VER IN G   D A T A ,  B R IN G IN G  CON TR O L


                                            www . hw m gl o b a l .co m