Page 133 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 133

340 PUTLOG SCAFFOLDING
      • Use: Not permitted.

350 ONE PIECE SILLS/ THRESHOLDS
      • Bed joints: Leave open except under:
          - End bearings.
          - Masonry mullions.
      • Pointing on completion: Mortar to match adjacent work.

360 OPENINGS
      • Method of forming: Rigid templates, accurately fabricated to the required size.

370 JOGGLE JOINTS
      • General: Fill with bedding mortar. Tamp to expel air.

390 POINTING
      • Joint preparation: Rake out to depth of 7-10 mm as work proceeds. Remove debris.
          Dampen surface.
      • Mortar application: Neat and consistent.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01