840 STRUTTING TO FLOOR JOINTS
      • Type: One of the following:
          - Herringbone strutting: At least 38 x 38 mm softwood.
          - Solid strutting: At least 38 mm thick softwood and at least three quarters of joist
             depth.
          - Proprietary metal strutting: approved types only.
      • Fixing: Between joists as follows:
          - Joist spans of 2.5 to 4.5 m: One row at centre span.
          - Joist spans over 4.5 m: Two rows equally spaced.
          - Strutting must not project beyond top and bottom edges of joists.
      • Outer joists: Blocked solidly to perimeter walls.

910 EAVES SOFFIT VENTILATION
      • Soffit boards: Fixed to leave a continuous ventilation opening not less than 10 mm
          wide for full length of eaves.
      • Insect mesh: A 3-4 mm mesh screen fixed across the opening to prevent large
          insect entry.