Page 290 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 290

840 LAYING PRECAST CONCRETE PAVING SLABS
      • Condition of substrate: Clean.
      • Setting out: Minimize cutting.
      • Joints: Open.
          - Width: 3 mm .
          - Perimeter/ Upstand margins: site specific mm wide, stone ballast filled.
      • Completion: Slabs must be level and stable.

870 APPLYING CHIPPINGS
      • Condition of substrate: Clean.
      • Gravel guards: Fit to outlets.
      • Dressing compound: Hot or cold application. Evenly pour at
      • 1.5 kg/m².
      • Chippings application (approximately): 16 kg/m².
      • Completion: Remove loose excess chippings without exposing dressing compound.

874 APPLYING SOLAR REFLECTIVE PAINTS
      • Application: manufacturers recomendation.
      • Surface coverage: Even and full.
      • Coats: Fully adhered.

          COMPLETION

910 INSPECTION
      • Interim and final roof inspections: Submit reports.

920 ELECTRONIC ROOF INTEGRITY TEST
      • Testing authority: The roofing contractor.
      • Timing of test: Give notice.
      • Condition of roof prior to testing:
          - Complete to a stage where integrity can be tested.
          - Surface: Clean.
      • Test results and warranty: Submit on completion of testing.

940 COMPLETION
      • Roof areas: Clean.
      • Outlets: Clear.
      • Work necessary to provide a weathertight finish: Complete.
      • Storage of materials on finished surface: Not permitted.
      • Completed membrane: Do not damage. Protect from chemicals, traffic and
          adjacent or high level working.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01
   285   286   287   288   289   290   291   292   293   294   295