Page 550 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 550
530 FACTORY INSPECTIONS AND TESTING
• Notice before inspection and testing: 14 d.
• Equipment to be inspected and tested:
- Carriage assembly;
- Drive mechanism; and
- Rail assembly.
• Factory inspections of fabrication: Not required.
• Factory testing of assembly: Not required.
EXECUTION
610 STRIPPING OUT
• Extent of stripping out: Complete installation.
620 INSTALLATION GENERALLY
• Standard: In accordance with BS 6440.
630 LAYOUT AND LOCATION
• General: site specific.
COMPLETION
910 TESTING AND COMMISSIONING
• Standard: In accordance with BS 6440 Appendix A.
• Operational tests: Undertake.
• Test certificate: Submit.
- Number of copies: 2.
920 ELECTRICAL INSPECTION AND TESTING
• Electrical inspection and testing: as M+E performance specification.
925 NOTICES, INSTRUCTIONS AND CERTIFICATES
• Standard: In accordance with BS 6440 Appendix A.
• Emergency stairlift evacuation procedure: Include within building operation and
maintenance manual.
• Wall mounted single line diagrams: Required.
- Content: Describe the power distribution system serving the stairlift. Include
power sources, points of isolation and device ratings.
• Circuit charts for switchgear associated with the stairlift system: Required.
• Instruction manual: Required.
- Content: Drawings and diagrams necessary for normal use of the lift, emergency
use, rescue, maintenance, repair and periodic checking.
- Number of copies: 2.
• Maintenance instructions: To BS EN 13015.
• Log book: Individual for each stairlift.
- Type: Hard back cover embossed with the stairlift name and unique
identification reference, with A4 lined paper, minimum 100 pages.
• Certificates: Submit.
- Number of copies: 2.