Page 52 - B6118-AEW-XX-XX-PP-A-0001_(P17)_Contractors Manual
P. 52

DESIGN





       D3 Drive Thru (Exterior)






       D3.8 Entrance Vestibule

       All entrance  doors  should be  automated.  All
       McOpCo  restaurants  should  have  automated
       sliding doors but Franchisees may chose to
       retain their automated swinging doors.

       McDonald’s approved inspectors have provided
       the following guidance to assist welcome zone
       positioning, however, approval will be required
       on a site by site basis via Building Control or the
       Warrant System and must accommodate any
       means of escape requirements.


       England and Wales
       Lobbies must provide an uninterrupted, 850mm
       wide ‘slalom’ type movement between doors.
       Within the lobby a clear 1500mm turning circle
       must be available.

       Scotland
       Lobbies must be a minimum of 1.2m wide and
       allow  sufficient  space  for  a  person  to  pass
       where  a wheelchair  with assistance may also
       be present. The space usually  allocated for a
       ‘wheelchair and assistance’ if 1600 x 750mm.

       Northern Ireland
       Lobbies must be a minimum of 1.2m wide and
       allow  sufficient  space  for  a  person  to  pass
       where  a wheelchair  with assistance may also
       be present. The space usually  allocated for a
       ‘wheelchair  and  assistance’  if  1600  x  750mm.
       An  uninterrupted  850mm  wide  ‘slalom’  type
       movement  between  doors  should  also be
       maintained.

       Republic Of Ireland
       Lobbies must provide an uninterrupted, 850mm
       wide ‘slalom’ type movement between doors.
       Within the lobby a clear 1500mm turning circle
       must be available.  All entrance  doors  should
       have 1000mm minimum clear width.




        D3.8           Entrance Vestibule                  2.0                        23 June 2016