DESIGN





         D6 Overview of General Interior Décor Concept Elements






         D6.7 Self Order Kiosks (Acrelec NG32)

         McDonald’s have a number of self order kiosk           -  A minimum of 25% SOK’s must be accessible as
         (SOK)  solutions  allowing  some  flexibility  into      BS8300:2009+A1-2010 (figure 5). Where SOK’s
         the  design and  layout  in this area.  SOK’s are        are located in multiple areas of a restaurant
         available as:                                            (for example to two entrances), accessibility
                                                                  should be considered in each location.
         -  Freestanding, double sided units
         -  Wall mounted (single sided)                         -  Wall  mounted  kiosks should  be  set  out  to
                                                                  714mm to the underside of the restaurant floor
         SOK’s should  be  positioned  in  clear  view of         level.
         all  customers entering  the restaurant  and not
         impact on the circulation or seating spaces            Power and Data Requirements
         adjacent to them. A number of other parameters         Double sided kiosk          1x power       4x Lan
         must be considered:                                    Single sided kiosk          1x power       2x Lan

         -  SOK’s should be ideally located on the same         Weight
           side of the restaurant as the majority of seating.   Double sided kiosk          140kg
           This minimises the amount of customer  cross         Single sided kiosk          100kg
           over in the queuing areas.
                                                                Further SOK manufacturers information can be
         -  SOK’s should be no closer than 2m from the          found on Aconex at:
           entrance doors other than by acceptance of
           the Governance Team. This is to prevent the          Documents > Document Register > Restaurants
           appearance of queues close to the entrance           >  Supply Chain Bulletins >  Experience  of  the
           which will deter other customers from entering       Future IT Documentation
           the restaurant.

         -  SOK’s should be no closer than 3m from the
           service counter other than by acceptance of
           the Governance Team.


         -  Space for queuing people must be allowed
           to  each  operational  side of  the  SOK’s as
           demonstrated in the diagrams following.

         -  SOK’s must  not  impact  the  minimum 3.0m
           queue area and 1.8m path (including
           allowable queue space to each SOK) other
           than by acceptance of the Governance
           Team.

         -  Maintenance  access to  SOK’s must be
           maintained.






          D6.7           Self Order Kiosks                   5.0                        25 July 2017