Page 4 - Domino's Power and Data Requirements With Photographs August 2018
P. 4

Power and Data Schedule

             May 2018



             CSR Counter                                           Counter            1No 13 amp     Dirty   24 Hour     16 No. Cat   250W              Mandatory
                                                                   There are two      Spur Dirty     and     and none    5E RJ45
                                                                   6way power bars    Supply White   Clean
                                                                   fitted into the    Face Plate.                        Increased
                                                                   cabinets           Plus 2No 13                        to 16 cat
                                                                                      amp Clean                          5E for IT
                                                                   10 mt VGA to all   Supply Red
                                                                   and any Slave      Faceplate.                         Data to
                                                                   Screens            Install VGA                        terminate
                                                                                      Cable to                           in the
                                                                                      Collect Screen                     office
                                                                                                                         comms
                                                                                                                         cabinet
                                                                                                                         data rails
             CSR Counter                                           Screens located    13 amp         Clean   Switched    None        250W      12w      Mandatory
             Screens                                               on top of counter  socket, Green   Eco    by last
                                                                                      Face plate             man out
                                                                                                             switch
             CSR Counter                                           Counter outer      13 amp socket  Clean   No          None        250w      23W      Mandatory
             cash drawer                                           shelves



             CSR Counter                                           Host located in    13 amp socket  clean   24 hour     Fits to     250W      210W     Mandatory
             Host                                                  counter                                               counter
                                                                   cupboard, if not                                      data rail
                                                                   located within
                                                                   comms Cabinet

             CSR counter                                           Slave located in   13 amp socket  Clean   24 hour     Fits to     250W      65W      Mandatory
             Slave                                                 counter cupboard                                      counter
                                                                                                                         data rail
             CSR Counter                                           Counter middle     13 amp socket  clean   No          Fits to     250W      23W      Mandatory
             Receipt                                               shelf                                                 counter
             Printer                                                                                                     data rail

             CSR Counter                                           Counter Middle     13 amp socket  clean   No          Fits to               100W     Mandatory
             Thermal                                               Shelf                                                 counter
             label Printer                                                                                               data rail


             PDQ                                                   Top of counter     13 amp socket  Dirty   No                      250W               Mandatory
             Machines
             Counter                                               Counter                                   24 hour     6 No. Cat   250W      Nil      Mandatory
             Phone                                                                                                       5E RJ45
             Hearing                                               Counter            13 Amp         Dirty   No          None        250W      12W      Mandatory
             Loop                                                                     Socket
             Menu                                                  Above Counter,     1No 13 Amp     Clean   Switched    1No. Cat5E  250W               Mandatory
             Screens                                               Within Ceiling     Socket per     ECO     by last     RJ45 per                       Unless
                                                                   Void               Screen.  Green         man out     screen                         Bottom
                                                                                      face plate. To         switch                                     Edge is Less
                                                                                      be located                         Data to                        Than 2020
                                                                                      above each                         terminate                      From
                                                                                      screen                             in the                         Finished
                                                                                                                         office data                    Floor Level
                                                                                                                         rails


             Menu                                                  Media player to    Comms          Dirty   24 hour
             Screen                                                be located in the   Cabinet  top
             Media                                                 office comms       power bar
             Players                                               cabinet, top
                                                                   compartment
                                                                   mounted on the
                                                                   side wall
             Prep Screen                                           Above Slap table.   13 Amp        Clean   Switched                250W      24W      Mandatory
             above Slap                                            Note can be        Socket, Green   ECO    by last
             table                                                 installed in wall   Faceplate             man out
                                                                   mounted shroud     2000 Above             switch
                                                                   or via a ceiling   Finish Floor
                                                                   mounted pole       Level







             Prep Screen                                           Above Slap table.   13 Amp        Clean   24 hour     1 No. Cat   250W      65 W     Mandatory
             Slave                                                 Note can be        Socket, Black                      5E RJ45
                                                                   installed in wall   face plate
                                                                                        4
   1   2   3   4   5   6   7   8   9