Page 8 - LINK - Graphics- Printflow latest library & Wall Prep Doc
P. 8

Biscuit Joint Panel Fixing:
MDF Panels to have preferred
biscuit joint fixing method to
prevent bowing. All remaining
joints filled with 2 part quick
drying filler and sanded to flush
and flat finish.
N.B: 2 Part quick drying filler
must be used in all area’s of
application.

Scaffolding positions:
All contractors scaffolding to leave a
working minimum distance of 500mm.
Graphic fitters can supply and use
their own but shared contractors
scaffold is preferable in order to save
time.

                            Panel Movement Issues:
                              See example of incorrectly
                              finished panels, movement
                              and bowing can occur after
                              graphics are fitted and
                              finished. Biscuit joints reduce
                              this effect on all elevations.
                              Ripple in graphic shown
                              here has been caused by
                              joins between MDF boards.
                              The example shown has
                              occured three months post-
                              install due to the MDF
                              boards becoming loose
                              beneath the wallcovering.
                              This can be prevented by
                              screwing MDF boards in
                              place.
   3   4   5   6   7   8