Page 9 - Foster Cold Room Microsoft Word - V3 Fusion Fusion Scroll Technical Manual 01 03 2015.docx
P. 9
Specifications
Performance Data: Medium Temperature (R407F)
R407F Cooling Capacity (Watts) Absorbed Power (Watts)
TE
Unit M odel HP -20 -15 -10 -5 0 5 10 -20 -15 -10 -5 0 5 10
TA
27 941 1231 1550 1943 2374 541 574 610 651 693
JEHR-0050-B1-M -1 0.50
R407F 32 882 1126 1423 1776 2195 611 647 701 765 841
38 823 1050 1324 1654 2047 626 678 740 813 900
27 1257 1672 2136 2706 3342 709 755 800 847 895
JEHR-0067-B1-M -1 0.67
R407F 32 1187 1510 1934 2432 3034 744 791 885 964 1022
Series 1 38 1484 1385 1764 2218 3804 862 825 1000 1078 1100
906
755
996
2761
1071
27
1162
929
1957
3112
2479
JEHR-0100-B1-M -1
R407F 1.00 32 1449 1775 2249 2810 3469 904 970 1068 1181 1312
38 1275 1636 2065 2571 3172 912 1008 1117 1245 1393
27 1811 2399 3037 3795 4631 1009 1103 1203 1315 1434
JEHR-0113-B1-M -1
R407F 1.13 32 1706 2162 2739 3412 4191 1075 1149 1283 1479 1614
38 1532 1974 2571 3096 3796 1064 1193 1328 1512 1711
27 2325 3061 3870 4870 1163 1252 1347 1451
JEHR-0140-B2-M -1/3 1.40 32 2151 2780 3534 4439 1204 1316 1444 1591
R407F
38 1981 2562 3263 4013 1253 1380 1523 1705
27 1790 2450 3050 3760 4460 1070 1170 1260 1360 1470
JEHR-0150-B2-M -1/3 1.50 32 1600 2240 2800 3500 4240 1090 1200 1310 1410 1520
R407F
38 2010 2510 3180 3920 1240 1360 1480 1590
27 2900 3540 4230 4940 5610 1460 1490 1540 1640 1780
JEHS-0200-B2-M -1/3 2.00 32 2670 3300 3980 4690 5410 1650 1680 1720 1780 1900
R407F
Series 2 38 3500 4230 3610 4320 5060 1740 1940 1970 2030 2340
2950
2100
27
1820
1930
2100
5010
5810
6560
JEHS-0250-B2-M -1/3
R407F 2.50 32 3260 3970 4750 5570 6400 1950 2030 2120 2260 2450
38 3610 4370 5200 6080 2300 2390 2510 2650
27 4150 5030 5920 6790 7500 2110 2240 2400 2660 3030
JEHS-0300-B2-M -1/3
R407F 3.00 32 3860 4710 5610 6510 7350 2360 2480 2630 2840 3130
38 4260 5140 6050 6980 2810 2950 3130 3350
27 4420 5320 6340 7320 8120 2920 3110 3300 3610 4110
JEHS-0350-B2-M -1/3 3.50 32 4900 5960 7020 8040 3430 3590 3820 4170
R407F
38
TE: Evaporating Temperature (°C)
TA: Ambient Temperature (°C)
Rating Condition: Suction Gas Superheat 10K, Sub cooling 0K
Recommended superheat: 5K to 20K
For applications above 0°Cte, the compressor suction gas temperature must not exceed 20°C
Maximum cut‐out setting of the HP switch must not exceed 26 bar
Data presented in accordance with BS EN 13215:2000
Issue: 01.03.2015 Page 8