Page 27 - P11110_AEW_XX_XX_PP_A_0001_(P02)_CO-OP LEAN STORE DESIGN MANUAL
P. 27
B
B.3 Separating wall details
START START
Is the building
Yes less than No Is the floor a ground
280m2 (3014ft)? bearing slab?
Yes No
No fire Is the BOH less
compartmentalisation Yes than 1/3rd of the No
required total area of the
building?
Is there an
opportunity to
co-ordinate
with the
developer?
Review asset
plan with view of Yes No
No reducing BOH Yes
Closed Is the ceiling Open area to 1/3rd of
open or closed? total area
Work with
Utilise wind post developer to install Utilise head restraint
detail pockets for wind detail
posts
Full height fire
compartment wall Lean Lean Cost saving
required store store opportunity
Is the ceiling Cost saving principle principle lost
height greater Greater Partition wall to be opportunity
2400mm as per
or less than standard detail lost
2600mm?
Lean
store
principle
Less
NOTE:
Please ensure compliance with Part B - Fire
Full height fire Safety.
compartment wall
required Follow the link below for further information
on exemplar fire safety.
Cost saving
opportunity 3.1-RCS-RHSE-(110)-269 Food Store Fire
lost
Design Technical Specification .._ (004)
B.3 Separating wall details 2.0 14th June 2019