Page 38 - P11110_AEW_XX_XX_PP_A_0001_(P02)_CO-OP LEAN STORE DESIGN MANUAL
P. 38

B








        B.8 Costa pod provision



                                                                                                                                                                  General Description of Service Requirement
                                                                                                                                                                 Service Installation Specification
        See below overview of the costa pod provision required at a lean store.
                                                                                                                                                                   •
                                                                                                                                                                      The Costa Express  Station requires  a  water supply, electricity and  waste discharge pipe
                                                                                                                                                                      work.
                                                                                                                                                                   •
                                                                                                                                                                      The services are to be installed at a pre-set height and location in order to be fed into the rear of
        For full assembly information please refer to detailed document:                                                                                         MK2/MK3
                                                                                                                                                                      the concession through a rectangular hole measuring approximately 500mm x 300mm.

        ‘Costa Coffee Service Installation Specification MK2 and MK3’                                                                                              IMPORTANT

                                                                                                                                                                 Services Location When Installing From the Ceiling
                                                                                                                                                                   It is the responsibility of the site to install these services to this specification.


                                                                                                                                                                              Services Location When Installing From the Ceiling
                                                                                                                                                                 Viewed from Front of Station.

                                       View                                                                                                                                         Viewed from Front of Station.
                                         A
                                                                                                                                                                  32mm Plastic Waste.

                                                                                                                                                                  32mm Plastic Waste                 STORE CEILING
                                                                                                                                                                  terminated above ceiling
                                                                                                                                                                  in recommended fittings
                                                                                                                                                                  listed below. Complete with
                                                                                                                                                                  ¾” Internal Diameter                             GENERAL DIMENSIONS

                                                                                                                                                                  flexible pipe run down
                                                                                                                                                                  wall or column (if used)                         OF COSTA
                                                                                                                                                                  and 1 metre left protruding                      EXPRESS STATION
                                                                                                                                                                     Watch out for stairs, lifts
                                                                                                                                                                  towards the unit (or from                        IMPORTANT!
                                                                                                                                                                     and doors
                                                                                                                                                                  front of column)                                 Be aware that you must provide
                                                                                                                                                                                                                   enough space for the Costa
                                                                                                                                                                 Electrical outlet 13 amp                          Express Station when the doors
                                                                                                                                                                 socket positioned at                              are OPEN and CLOSED.
                                                                                                                                                                 2200mm from FFL.                                  Dimensions for both situations
                                                                                                                                                                 Central to unit width or                          are below.
                                                                                                                                                                 on rear of column if fitted.
                                                                                                                                                                                                                   Height
                                                                                                                                                                                                                   Doors open or closed 1980mm.
                                                                                                                                                                                                                   Width
                                                                                                                                                                                                                   Doors closed 800mm.
                                                                                                                                                                                                                   Doors open 900mm.
                                                                                                                                                                 Termination of Cold Water                         Depth Front to Back
                                                                                                                                                                 Supply at 660mm from FFL                          Doors closed 1000mm
                                                                                                                                                                 and central. This should                          Doors open 1700mm
                                                                                                                                                                 protrude forwards no more
                                                                                                                                                                 than 50mm from the rear
                                                                                                                                                                 wall or gondola end.                              ADDITIONAL
                                                                                                                                                                                                                   CLEARANCE
                                                                                                                                                                 Pressure reducing valve                           Sides 17.5mm each side
                                                                                                                                                                                                                   (35mm total)
                                                                                                                                                                 set to 3 bar
                                                                                                                                                                                                                   Top 20mm
                                                                                                                                                                                                                   Rear 50mm
                                                                                                                                                                 Washing machine                                   Waste in ¾” internal
                                                                                                                                                                 tap                                               diameter flexible
                                                                                                                                                                                                                   plastic pipe. Leave 2
                                                                                                                                                                                                                   metres spare for final

                                                                                                                                                                                                                   connection.
                                                  Store Entrance
                                                                                                                                                                 Services rear entry area.
                                                                                                                                                                 Size 500 wide x 300 high.
                                                                                                                                                                 Positioned centrally across unit and
                                                                                                                                                                 400mm from FFL.
         Part plan                                                                          View A                                                            Costa Pod Services                  5 of 14
         Above shows the proximity of the Costa pod to the customer entrance and egress      Above shows the location of the drainage pop-up for the Costa pod  Extract page 7 from Costa Coffee Service Installation Specification MK2 and MK3
                                                                                                                                                                                                                             MK2/MK3 | pg 7