Page 356 - B6118-AEW-XX-XX-PP-A-0001_(P18)_Contractors Manual
P. 356

CONSTRUCT

























                 Common Tiling Scenarios - Floors
                 PLYWOOD FLOORS




                 •  Tiling to timber floors - dry areas
                 •  Internal floors                                            PREMIUM PERF ORMANCE




                    1.  Ensure that the subfloor is made of    2.  Prime the flooring grade Plywood   3.  Fix the tiles to the primed floor using
                    suitable flooring grade plywood and is   using neat ARDEX P51 Primer and allow   ARDEX X7001 Microtec Fibre Reinforced
                    secured in accordance with BS: 8385.  to dry.            Tile Adhesive.












                                                         NEW FLOOR TILES















                                                           PLYWOOD













                                                                      4.  Grout the joints using ARDEX-FLEX FL
                                                                      Flexible Tile Grout.

       C3.2            Ceramic Tiling                      2.0                        09 January 2015