Page 26 - CRC • MRO CATALOG
P. 26
CORROSION INHIBITORS
PRODUCT Appearance Corrosion Protection Drying Time Specifications SDS Label Container Size
(to touch)
Attached
SP-350™ Thin, Non-Drying Indoors – Non-Drying NSF H2 Registered Yes 16 5
Up to 2 Years
Indoors & NSF H2 Registered,
SP-400™ Waxy Outdoors – 1 Hour Meets requirements of MIL-C-16173 Yes 16 5
Up to 2 Years Grade 4 (corrosion test only)
Battery Terminal Apply every 3-4
Protector Viscous months Non-Drying N/A Yes 12
Meets Requirements ASTM 780A, Mil-P-26915,
ASTM B117 Salt Mil-P-46105, MIL-P 21035B (Aerosol)
Zinc-It ® Dry, Zinc Spray: 2300 hours 15 to 30 Yes 16
average Minutes Meets Requirements of MiL-P 26915, 1
MiL-P 46105 (Bulk)
ASTM B117 Salt
Bright Zinc-It ® Dry, Zinc, Spray: 2300 hours 15 to 30 ASTM-A780 Yes 16
Shiny Finish Minutes
average
Rust Milky Paint/coating for
Converter Emulsion steel 1 Hour N/A No 1
Aerosol: Meets ASTM-A-780 Requirements
ASTM B117 Salt
Brite Zinc ® Dry Spray: 2000 hours 15 minutes Bulk: ASTM-A-780 DOD-P-2103B, No 16
average MIL-P-46105, MIL-P-26915B, SSPC PS-12, SSPC 1
PS-20, SSPC PS-22, SSPC PS-29 SSPC PS-30
ASTM-A-780, DOD-P-21035A,
®
1st Zinc Cold ASTM B117 Salt 15 to 30 MIL-P26915, MIL-P-46105
Galvanizing Primer Dry Spray: 2000 hours minutes SSPC PS-12, SSPC PS-20, SSPC PS-22, SSPC Yes 16
average
PS-29, SSPC PS-30
Visit crcindustries.com or call 800-556-5074 for more information.
24 crcindustries.com