P. 20

IGEM/G/4 Edition 2
             filter outlet valve (FOV)
             Valve fitted downstream of, and adjacent to, a filter to shut off the supply of gas.

             fixed factor conversion
             Means of converting metered gas consumptions from actual conditions to reference conditions
             by means  of a multiplying factor which  takes account of temperature and/or pressure
             (including compressibility)  and which  is based upon the assumed constant metering
             temperature and/or pressure (including compressibility), as appropriate.

             flame detector
             That part  of a flame safeguard which is responsive to flame properties and signals the
             presence of flame.

             flame failure
             Loss of flame from the normally-detected  position by any cause other than the action of
             de-energising the safety shut-off system.

             flame safeguard
             Control responsive to flame properties detecting the presence of flame and, in the event of
             ignition failure or subsequent loss of flame, causing safety shut-down and/or lockout.

             flame simulation
             Condition in which a flame detector signals the presence of flame (whether or not it exists).

             flammability limits
             lower flammability limit (LFL):     Concentration of flammable gas or vapour in air, below
                                                 which the gas atmosphere is not flammable.

             upper flammability limit (UFL):     Concentration  of flammable gas  or vapour in air, above
                                                 which the gas atmosphere is not flammable.

             Note:   Although a mixture which has a concentration above UFL is not a flammable gas atmosphere, it can readily
                    become so and, in certain cases for hazardous area classification purposes, it is considered as a flammable
                    gas atmosphere.

             flooding holes, relating to a watersealed gasholder
             Holes in a cup plate which allow the cup to fill and empty with water without overflowing or
             gas release and enable the changes in water levels as a gasholder cups and uncups to take
             place more easily.

             flow computer
             Device that utilises a high frequency signal and calculates a standard cumulative flow of gas
             based on this signal, pre-programmed parameters and other gas properties  determined by
             suitable transducers.

             flow straightener
             Series of plates or tubes used to remove turbulence in the combustion air or gas flow which is
             caused by air or gas passing through an obstruction such as a bend.

             flue
             Passage for conveying combustion products to outside air within a chimney.

             flue break
             Opening into a secondary flue in the same room as, and in addition to,  the opening at a
             draught diverter.

             flue lining
             Wall of a chimney, consisting of  components the surface of which is in contact with  the
             products of combustion.