IGEM/G/4 Edition 2
             modification
             Temporary or permanent physical change to any aspect to an existing installation or design.

             molecular seal
             Device designed to prevent mixing of air and gas to a flammable concentration upstream of
             the position of the seal.

             monitor/active (regulator)
             Arrangement of two regulating devices in series whose pressure settings are stepped so as to
             allow one (active) normally to control the outlet pressure and the other (monitor) to assume
             control in the event of failure of the active device to the open position.

             multiple vent
             System of vents whereby gas is discharged to atmosphere by simultaneous venting from two
             or more adjacent vent stacks.

             multi-storey
             Containing more than one storey, either  above or  below ground but  not including a
             basement/cellar.

             natural draught burner
             Burner not requiring a fan or other mechanical means to supply combustion air.

             natural draught flue system
             Flue system in which the draught is provided by the thermal force arising from the heat of the
             products of combustion.

             near miss
             Incident arising out of, or in connection with, work which did not cause injury to any person
             and was not a “dangerous occurrence” but which might easily have caused an injury.

             network
             Part of the Network, a network comprises  interconnecting pipes which are downstream of a
             gas reception terminal, processing facility, storage facility or importing interconnector, and
             used for the conveyance of gas to consumers  as defined in the Gas Safety (Management)
             Regulations (GS(M)R).

             network analysis
             Modelling of a pipe system to simulate flows and pressures  assuming that instantaneous
             supplies and demands are identical.

             network analysis, transient
             Modelling of the pipe system to simulate flows and pressures, taking into account that supplies
             and demands will vary with time, and may not match.

             network controller
             Suitably qualified engineer appointed by the Responsible Engineer (RE) to be the point of
             contact for all internal and external organisations.

             node, relating to network design
             Notional point on a gas supply system, used in network analysis, to identify a junction of two
             or more pipe sections, including a change in pipe diameter or material or used to allocate gas
             demands to the system.

             noggins
             Horizontal timber rails fitted between studs in the wall panels to provide fixing points.

             non-controlled interface
             System interface where gas pressure and/or flow is not continuously controlled.