Performance Steps












































                                                             12e
                                              Evenly spaced and wrinkled free webril

                        e. With each turn overlap the webril by 1/2 -1/4 the previous wrap. The top of the webril should
                          bisect the middle of the previous layer covering up the shallow line and present evenly
                          applied padding. To reduce possible constrictive edema caused by applying webril too tight,
                          keep the webril on the extremity as it is applied.(Refer to Figure 3-x)

                  13. Prepare casting materials.
                        a. If using plaster rolls, go to step 16
                        b. If using fiberglass rolls, go to steps 14 and 15.
                  14. Place fiberglass casting gloves on hands.
                 CAUTION: To prevent chemical burns to the hands it is mandatory for the technician to use fiberglass
                 casting gloves
                  15. Open fiberglass casting package and go to step 16
                 NOTE: Open one fiberglass package at a time. As fiberglass comes in contact with the air, the roll will
                 start to cure (set up ).

                  16. Apply 1st plaster/fiberglass roll.
                 NOTE: Examination gloves are recommended to protect the technician's hands as the resin in the
                 plaster may cause the skin on the hands to dry up.

                        a. Hold plaster/fiberglass roll with one hand.