Page 7 - Statement of Qualifications
P. 7

RLC SERVICES




        Avangrid (CMP)
        Maine Power Reliability Program
        RLC provided system planning and engineering studies – including
        report writing and presentation before ISO-New England, Maine
        Public Utilities Commission and other regulatory stakeholders
        – for more than 550 miles of preliminary, alternate and selected
        transmission line routes. We assisted in the preparation of the permit
        applications for the Maine Department of Environmental Protection
        as well as other local and state permitting bodies. RLC also played
        a significant role in the construction sequence and planning for the
        MPRP proposed substation and transmission improvements.
        RLC has performed numerous analyses of MPRP’s potential impact
        on existing CMP substation facilities, including these studies:
         teady State Impacts on existing station equipment bus, breaker
          S
          and switch configurations;

          F
         ault Current Impacts on circuit breaker duty ratings, circuit
          breaker transient recovery voltage (TRV), bus support insulators,
          disconnect switches, grounding switches, line traps, capacitor
          banks, and shunt capacitors;
          S
         ystem Impacts on protection relays, shunt capacitor  settings,
          line relay applications, SPS systems, series capacitor, ground relay
          polarization and out-of-step stability.
        Eversource Energy
        New England East West Solution
        RLC provided reliability assessment of steady state and stability
        performance, including report writing and presentation before ISO-
        New England on the NEEWS Projects. We prepared the study reports
        and played a significant role in the I.3.9 review and approval process
        with the Transmission and Stability Task Force Groups.
        POWER DELIVERY

        RLC offers a comprehensive package of engineering, design and
        estimating services for Substations, Transmission Lines, Protection
        & Control, Relay Settings and Automation & Integration. Our
        substation and transmission facility design services range from
        12.47 kV to 345  kV. RLC’s Engineers have extensive experience with
        substation and switchyard design for transmission and distribution
        systems, as well as experience designing wind farm collector
        systems, transmission interconnection substations, and facilities
        for power plant and utility service applications. RLC leverages its
        design experience in combination with utilizing nationally recognized
        software (SAGE-Timberline) to support Level 1 through 4 cost-
        estimating efforts for our utility and energy developer clients.