Operating
Adjustment of channel-related
Dynamics settings
1 Channel selection.
2 [Side Chain]: Open the selection list with the right arrow button and select the desired setting pre- or post-EQ for
the Dynamics unit (CH1…CH12, ST1…ST12).
3 [Gate]: Press [IN] to enable or disable the function. When switched on, the function is deactivated.
Gate characteristic: The Y axis corresponds to the threshold value, and the X axis to the time factor. The curve pro‐
file corresponds to the signal behaviour with attack, hold, and release.
Controller for adjusting the signal settings of the gate function:
n [Threshold]: Threshold value in the range –80 dB…0 dB. Signals below threshold are not routed.
n [Attack]: Slew rate in the range 0.5 dB…100 dB. Default setting: 3 ms.
n [Hold]: Hold time in the range 2 ms…2000 ms. Default setting: 2 ms.
n [Release]: Release time in the range 2 ms…2 s. Default setting: 350 ms.
n [Depth]: Signal attenuation for signals below the threshold in the range 0 dB…–80 dB. Default setting: –80 dB.