Page 3 - moorVMS-LDF_Brochure
P. 3

moorVMS - Vascular Monitoring System                                                                                   MemoryChip Probes




            The moorVMS-LDF laser Doppler blood                The laser Doppler technique                                         Just plug in and monitor - calibration constants are stored   Applications
            flow monitor is a high performance, medical                                                                            within the robust, medical grade probe connector and
                                                                                                                                   are read by the monitor as soon as they are connected.
            grade module for clinic or laboratory.             Laser Doppler has become a gold standard for dynamic                Skin probes combine laser Doppler and temperature   The flexibility of the laser Doppler technique and the range
            Use of DSP technology brings you a                 microvascular blood flow assessments. Optic probes                  measurement all within the same probe head for     of probes has lead to many thousands of publications
                                                               are used to monitor blood flow in capillaries, venules and                                                             covering almost all tissue types, research areas and
            portable, lightweight module featuring             arterioles; vessels responsible for nutrition of the skin and       convenience.                                       medical disciplines. This means that we can usually
            uncompromised specifications and reliability       thermoregulation. The sampling depth depends on probe               The moorVMS-LDF will even remind you when you need   draw on published work and our own experience to
            at a breakthrough price. The features              design and tissue characteristics but is typically around           to re-calibrate or if a service is due. Bio-compatible   advise on a suitable system configuration and protocol
                                                               1mm.                                                                                                                   with confidence. Applications are often non-invasive and
            include;                                                                                                               materials that can be sterilised are used throughout to   may involve tests of microvascular function stimulated
                                                                   Optical fibre transmits   Optical fibre transmits               ensure safety for surgically invasive applications.
                                                                   laser light to the tissue  reflected/scattered                                                                     by changes in posture, vasoactive drug delivery by
            •   Single and dual channel options.                                             laser light to a                                                                         iontophoresis, heating and pressure; tracking changes
                                                                                             photo detector
            •   Multi-channel: combine modules for a multi-                                                                                                                           in flow with time or comparing flows from different
                channel system with software support for your ideal                                                                                                                   measurement sites.
                configuration. Stacking case design offers a compact
                footprint for multi-channel users.                                                                                                                                    Routine clinical uses are increasing and take advantage
            •   ‘MemoryChip’ probes: for a wide range of                                                                                                                              of the wide dynamic range to capture the cardiac cycle,
                applications. Calibration constants are stored within                                                                                                                 vasomotion effects or trends over hours, days or weeks.
                the probe itself with timed re-calibration reminders.                                 capillaries
            •   Easy viewing: high contrast, ice white, backlit                                                                                                                       Assessments include;
                                                                1mm
                LCD display.                                                                                                                                                          •   Post operative flap monitoring
            •   Advanced Windows  PC software: with extensive                                         arterioles                                                                      •   Prediction of amputation levels
                                 TM
                                                                                                      & venules
                analytical features and automatic report generation.                                                                                                                  •   Tooth pulp vitality testing
            •   Easily connectable: analogue output (0-5V, BNC)                                                                    Skin probes are available with twin or multi fibre   •   Endothelial function/dysfunction
                and digital (USB) real time data transfer included as                                                              configurations. Multi fibre designs usually employ a ring   •   Toe pressure assessment
                standard for connection to data acquisition systems.                                                               of collecting fibres around a central delivery fibre to   •   Pulse volume recording
            •   Medical grade design: for both clinical and    Low power laser light is transmitted via an optic fibre to          provide an averaged signal from a larger volume than the   •   Skin perfusion pressure
                research applications.                         the tissue. The light is scattered by tissue and moving             conventional twin fibre design. Both include temperature   •   Cerebral perfusion following injury
            •   Multilingual training DVD: for continual reference.  blood cells and its frequency is Doppler broadened.           measurement as standard.                           •   Post-occlusive reactive hyperaemia (see below)
            •   Reliable assured: industry leading 5 year
                manufacturers warranty.                        Some of the scattered light is collected by one or more             Endoscopic probes enable investigations of internal   Please contact us for no-obligation advice about your
                                                               optic fibres and transmitted to a photo detector.                   tissues such as colon, stomach, bronchus and urethra.  application and requirements.
                                                               The resulting photo current is electronically processed             Needle probes can be used for surface measurements
                                                               to produce the laser Doppler flux (blood flow) signal. The          where access is impaired (e.g. nasal, oral), inserted into
                                                               average Doppler frequency shift is directly proportional to         tissue bulk (e.g. muscle, cerebral, adipose) or used for
                                                               the average speed of the blood cells.
                                                                                                                                   direct single vessel measurements.
                                                               Changes in blood flow can be stimulated by a number                 Disposable probes are available for many experimental
                                                               of provocations including occlusion with a pressure cuff,           and clinical applications including post-operative flap
                                                               heating, the iontophoresis of vasoactive drugs, changes in          monitoring (e.g. buried and oral flaps) and measurement
                                                               the position of limbs etc.
                                                                                                                                   of cerebral perfusion. Disposable single fibre implantable
                                                                                                                                   probes are also available.


                                                                                                                                   Low profile designs are either used when access is
            moorVMS-LDF – single and dual channel modules with MemoryChip probes.
                                                                                                                                   difficult (e.g. oral flaps) or to reduce application pressure   moorVMS-PC screen shot – please refer to the moorVMS-PC software
                                                                                                                                                                                      brochure for further details.
                                                                                                                                   when the probe is covered by bandages.
   1   2   3   4