Page 22 - AFVi CNG & LNG Participant Guide
P. 22

Module 2: High-Pressure CNG Fuel System Components

             Fuel Receptacle       Equipped with a one-way flow check valve

                                       o  Prevents gas from flowing out of the
                                         fuel system
                                    Should always have a dust cover
                                    Check the O-ring condition
                                       o  Missing or damaged O-ring = unable
                                         to safely fuel vehicle









             Heavy-Duty Fuel
             Receptacles




















                                   Many heavy-duty natural gas vehicles have two sizes of 3,600 psi fuel receptacle
                                      o  The receptacle on the left is the larger receptacle, commonly referred to as the
                                         NGV1 Heavy-Duty (HD)
                                      o  The one on the right is the standard NGV1 receptacle.
                                   Both receptacles provide 3,600 psi fuel—but the NGV1 HD flows fuel at a faster rate

             Secondary Check        Redundant valve to prevent escape of gas
             Valve                    o  If receptacle check valve fails to seal
                                      o  If receptacle is damaged


















                                           NGV Essentials and Safety Practices (CNG & LNG)                            © 2024 AFVi All Rights Reserved    Page 2-4