Page 25 - Propane Vehicle Essentials and Safety Practices
P. 25
Propane ASME Tank Propane ASME Tank – Requirements
• No recertification required
• Sealed tank storing liquid and vapor • Tank data plate required
o 312 maximum psi
o 1,250 psi burst pressure • Pertinent markings
o Serial number
o Working pressure (312 psi)
• Designed for 80 percent liquid fill
o Metal thickness
o Year built
o Capacity
• Illegible or missing date plate
o Do not fill vehicle
o Decommission tank if data plate cannot be cleaned or a new one cannot be obtained
from manufacturer
9 10
Propane ASME Tank – Rust or Corrosion
• Propane tanks with rust or corrosion may be cleaned if recommended by
manufacturer
• If rust or corrosion seems excessive the tank should be de-commissioned and
inspected by an ASME-certified repair facility to ensure the tank can still be in service Lesson 3.3
Fuel Fill/Inlet Valve
Excessive Rust/Corrosion Acceptable/Repairable Damage
11 12
3