Propane ASME Tank                                        Propane ASME Tank – Requirements
                                                                                      • No recertification required
                     • Sealed tank storing liquid and vapor                           • Tank data plate required
                        o 312 maximum psi
                        o 1,250 psi burst pressure                                    • Pertinent markings
                                                                                         o Serial number
                                                                                         o Working pressure (312 psi)
                     • Designed for 80 percent liquid fill
                                                                                         o Metal thickness
                                                                                         o Year built
                                                                                         o Capacity
                                                                                      • Illegible or missing date plate
                                                                                         o Do not fill vehicle
                                                                                         o Decommission tank if data plate cannot be cleaned or a new one cannot be obtained
                                                                                           from manufacturer

                 9                                                                 10







                           Propane ASME Tank – Rust or Corrosion


                     • Propane tanks with rust or corrosion may be cleaned if recommended by
                      manufacturer
                     • If rust or corrosion seems excessive the tank should be de-commissioned and
                      inspected by an ASME-certified repair facility to ensure the tank can still be in service  Lesson 3.3

                                                                                                       Fuel Fill/Inlet Valve






                               Excessive Rust/Corrosion  Acceptable/Repairable Damage
                 11                                                                12




                                                                                                                                                       3
   20   21   22   23   24   25   26   27   28   29   30