Page 123 - CCM_Program_Reb_2023 (1)_Neat
P. 123

Severe Respiratory Illness











           1     What is the name of the      2    What are its specific objectives related to the Priority Unwanted
                 critical control for Severe
                                                   Event (PUE)?
                 Respiratory Illness?
          Dust containment and improvement   A system is in place to identify and control dust emissions from new plants and existing
          projects                           operations preventing the dust from exceeding worker exposure limits


           3     What are the critical        4     What are the activities      5     What can be sampled from
                 control performance
                                                    within the management
                                                                                       the set of activities for
                 requirements to meet the           systems that support               verification, providing a
                 objectives?                        having the critical control        clear image of the critical
                                                    able to do what is required?       control status?
          A site register is maintained indicating   The fugitive dust app or equivalent is   Site register ensuring locations identified
          all locations where dusts are or can be   used by sites to create a register of dust   as sources of dust
          generated                          generating locations and follow-up
                                             action plans                       Locations that are visibly producing dust
                                                                                are listed on the site register

          The content of silica and portland cement   The site register must indicate if dust   Site register for dust sources that
          in dust are indicated in the site register  sources contain silica or portland cement  indicate silica and portland cement
                                                                                content
                                                                                Laboratory records of dusts analysis for
                                                                                silica and portland cement content

          Regular inspections are performed at all   The site register must indicate the most   Inspection dates recorded in the site
          dust source locations              recent inspection of each dust source  register

          Design or project improvements are in   iCare is available to track improvement of   Action plans to ensure dust reduction
          place to repair locations that have been   dust corrective actions    activities planned and completed
          identified as dust sources


           6     What is the target performance for critical    7    What is the critical control performance
                                                                     trigger for shutdown, critical control review or
                 control?
                                                                     investigation?
          The site demonstrates a system of design and improvement   Industrial hygiene monitoring indicates a worker exposure
          projects to reduce worker exposures to silica and portland   exceeds a Holcim exposure limit
          cement
























          Creation date: 01/2022 • The latest and only controlled version of this document is available on the HSE intranet.