Page 106 - Ordinance Chapter 17
P. 106
or cause of action against the Village by reason of any liability that is or may be imposed on the
Village, on account of any such defect, imperfection, or any failure to repair the same.
17.85 – 17.89 RESERVED.
SITE STANDARDS
17.90 PURPOSE.
These standards are to ensure site construction and development in a manner which will result in
an appearance compatible with permitted uses in the zoning district and to protect adjacent
property from safety hazards such as tower failure or falling ice.
17.91 SITE SIZE AND TOWER SETBACKS.
(1) The site shall be of a size and shape sufficient to provide an adequate setback from the
base of the tower to any property line. Such setback shall be sufficient to:
(a) Provide for an adequate vegetative, topographic or other buffer, as provided in
this section.
(b) Preserve the privacy of adjoining properties.
(c) Protect adjoining properties from the potential impact of tower failure and falling
ice by being large enough in area to accommodate such failure and falling ice on
the site.
(d) Conform to the minimum shore yard setbacks.
(2) Setbacks shall not be less than the height of the tower above grade between the base of
the tower and any property line. If the applicant presents to the Plan Commission a report
by a structural engineer licensed by the State of Wisconsin certifying the fall-down radius
of the proposed tower to be less than its height, the allowed set back shall be that certified
distance.
(3) When more than one (1) tower is placed on a site, all setback, design and landscape
requirements shall be met as to each tower. Structures may be located as close to each
other as technically feasible, provided tower failure characteristics of each tower on the
site will not lead to multiple failures in the event that one (1) fails.