Page 62 - Microsoft Word - Chapter 17 - Zoning Code .docx
P. 62

District shall apply to the Industrial/Business Park District; otherwise no
                setback shall be required.

        (d) Rear Yard.

                1. There shall be a rear yard having a minimum depth of 20’ for a
                         building 2 stories or less in height.

                2. For each additional story or fractional story in height the depth of
                         such rear yard shall be increased 3’.

        (e) Vision Clearance. No building erected at the intersection of 2 or more
                streets, where a setback of less than 10’ exists or is provided, shall hereafter
                be erected or structurally altered for any purpose unless a vision clearance
                triangle, free of visual obstruction of any kind, is provided at the corner of
                the building nearest such intersection. Such vision clearance triangle shall
                extend not less than 10’ horizontally along each street line from the
                intersection of their rights-of-way and shall extend vertically from the curb
                line to the ceiling line of the ground floor, but in no case shall such vision
                clearance triangle be less than 10’ high.

(3) HEIGHT AND AREA EXCEPTIONS

The regulations contained herein relating to the height of buildings and the size of yards
and other open spaces shall be subject to the following exceptions:

        (a) Architectural projections, such as spires, belfries, cupolas, domes, flues and
                chimneys, are limited to a height 200 feet.

        (b) Special structures, such as elevator penthouses, gas tanks, radio and
                television receiving antennas, manufacturing equipment and necessary
                mechanical appurtenances, cooling towers, fire towers, substations and
                smoke stacks, are limited to a height of 350 feet.

        (c) Essential services, utilities, water towers, electric power and
                communication transmission lines are limited to a height of 350 feet.

        (d) Communication structures, such as radio and television transmission,
                receiving, and relay towers and aerial towers, shall not in any event exceed
                in height of 350 feet, provided, however that any such structure, aerial or
                tower, if located within three (3) miles of a boundary line of an airport and
                landing strips, may not exceed the height limitations of the district in which
                it is located without prior proof of written notification of the public hearing