Page 45 - Lewisham SuDS DESIGN & EVALUATION
P. 45

7.4.9  Preliminary flow and volume calculations

      It is convenient to consider flow and volume           comparison of storage values between similar
      requirements at this stage in the design               sites.
      process to ensure that natural losses are
                                                             Expressing storage as ‘volume per m 2   ’ allows
      replicated and sufficient volumes of runoff            the designer to allocate storage throughout a         Concept Design
      can be temporarily accommodated to allow
                                                             site in discrete sub-catchments, and provides
      for discharge from site via a flow control             a straightforward way for the evaluation team
      and/or infiltration.
                                                             to check that calculated storage volumes are

      In some circumstances, for example where               acceptable.
      development is speculative, it may be                  Ideally each sub-catchment will manage its
      acceptable for the Concept Stage to omit               own runoff up to the 1 in 100 year return
      flow and volume calculations, but a Modified           period rainfall event. Where this is not viable,
      Flow Route analysis will be required to show           part of the storage volume will be provided
      that runoff can be effectively conveyed to a           depending upon the opportunities for
      discharge location.                                    storage within the subcatchment, with all

      Storage volumes are usually presented as a             residual flows cascaded into an adjacent
      single volume.                                         sub-catchment or ‘site control’.

      This form of expression encourages the ‘pipe           This approach maximises the opportunity for
      to pond’ practice and prevents simple                  storage throughout the development.


                                                                                                                   40
                                                                                      Flow control with
                                                                                      controlled discharge
                                                  C1
                                                 1 in 2                               from one catchment to
                                                                                      the next
                                                                C2
                                                              1 in 10                 Residual flows
                                          C3
                                        1 in 30
                   C4
                1 in 100 yr (+CCA)
                 + residual flows from
                     C1, C2 & C3 upto
                      1 in 100 yr (+CCA)




                                                             In this example the first three catchments
                                                             (C1, C2 & C3) only partially attenuate their
      Each catchment may only control and attenuate          own runoff, with residual flows passing into
      runoff up to lesser rainfall events (eg. 1 in 2        catchment C4 where these residual flows must
      years, 1 in 10 year, 1 in 30 years) with residual      be attenuated, along with C4’s own runoff, to
      flows passing into the next subcatchment.              the maixmum design storm (eg. 1 in 100 + CCA).


      Lewisham Council SuDS D & E Guide                                                                       © 2018 McCloy Consulting & Robert Bray Associates