4 Machining
flange sisi R
5 Gap Check Before :
Cover vs Shaft R Front = 0.15 mm
Steam Chest R Rear = 0.45 mm
after L Front = 0.05 mm
machining L Rear = 0.05 mm
After :
R Front = 0.05 mm
R Rear = 0.15 mm
L Front = 0.05 mm
L Rear = 0.05 mm
6 NDT Test Result acceptable
Penetrant
Steam Chest