Page 184 - 2018_IRC
P. 184
FLOORS
C-SHAPED
INSIDE TRACK
4 NO. 8 SCREWS
THROUGH WEB OR
FLANGES AT EACH
SIDE OF SPLICE
6 IN. MINIMUM
TRACK
For SI: 1 inch = 25.4 mm.
FIGURE R505.3.7
TRACK SPLICE
JOIST
HEADER
JOIST (TYP.)
6FT MAXIMUM
CLIP ANGLE JOIST
JOIST
TRIMMER JOIST (TYP.)
For SI: 1 foot = 304.8 mm.
FIGURE R505.3.8(1)
COLD-FORMED STEEL FLOOR CONSTRUCTION—6-FOOT FLOOR OPENING