Page 271 - 2018_IRC
P. 271
WALL CONSTRUCTION
BEND SECTION OR CLIP FLANGE
TO FORM VERTICAL
1½″ x33MIL
FLAT STRIP (MINIMUM)
WALL FRAMING
TRACK/STUD BLOCKING @ ENDS OF
STRAP & INTERMITTENTLY EVERY 12′
2 NO. 8 SCREWS @ STRAP TO BLOCKING
NO. 8 SCREW
@ EACH STRAP TO STUD
For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm, 1 foot = 304.8 mm.
FIGURE R603.3.3(1)
STUD BRACING WITH STRAPPING ONLY
STUD/TRACK BLOCKING
@ EACH END OF STRAP
& INTERMITTENTLY EVERY 12′
WALL FRAMING
WALL SHEATHING
1½″x33MIL
FLAT STRAP
BEND SECTION OR CLIP
FLANGE TO FORM VERTICAL
2 NO. 8 SCREWS
@ STRAP TO BLOCKING
NO. 8 SCREW
@ EACH STRAP TO STUD
For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm, 1 foot = 304.8 mm.
FIGURE R603.3.3(2)
STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
246 2018 INTERNATIONAL RESIDENTIAL CODE ®
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.