Page 80 - 2018_IRC
P. 80

BUILDING PLANNING



                       from  the  foundation  to  the  uppermost  story  in   (2438  mm)  in  width  in  the  wall  below  pro-
                       which they are required.                               vided  that  the  opening  includes  a  header  in
                         Exception:  For  wood  light-frame  construc-        accordance with all of the following:
                         tion,  floors  with  cantilevers  or  setbacks  not     1. The  building  width,  loading  condition
                         exceeding four times the nominal depth of the             and framing member species limitations
                         wood  floor  joists  are  permitted  to  support          of Table R602.7(1) shall apply.
                         braced wall panels that are out of plane with           2. The header is composed of:
                         braced wall panels below provided that all of               2.1. Not less than one 2 × 12 or two
                         the following are satisfied:
                                                                                         2 × 10 for an opening not more
                           1. Floor joists are nominal 2 inches by 10                    than 4 feet (1219 mm) wide.
                              inches  (51  mm  by  254  mm)  or  larger              2.2. Not less than two 2 × 12 or three
                              and spaced not more than 16 inches (406                    2 × 10 for an opening not more
                              mm) on center.
                                                                                         than 6 feet (1829 mm) in width.
                           2. The  ratio  of  the  back  span  to  the               2.3. Not less than three 2 × 12 or four
                              cantilever is not less than 2 to 1.                        2 × 10 for an opening not more
                           3. Floor  joists  at  ends  of  braced wall                   than 8 feet (2438 mm) in width.
                              panels are doubled.                                3. The  entire  length  of  the  braced wall
                           4. Fo   wood-frame   construction,   a                  panel does not occur over an opening in
                              continuous rim joist is connected to ends            the wall below.
                              of  cantilever  joists.  Where  spliced,  the  4. Floor  and  roof  opening.  Conditions  where  an
                              rim  joists  shall  be  spliced  using  a     opening in a floor or roof exceeds the lesser of 12
                              galvanized metal tie not less than 0.058      feet (3658 mm) or 50 percent of the least floor or
                                                       1
                              inch (1.5 mm) (16 gage) and 1 /  inches       roof dimension.
                                                        2
                              (38  mm)  wide  fastened  with  six  16d
                              nails  on  each  side  of  the  splice;  or  a  5. Floor level offset. Conditions where portions of
                              block of the same size as the rim joist       a floor level are vertically offset.
                              and  of  sufficient  length  to  fit  securely  Exceptions:
                              between  the  joist  space  at  which  the         1. Frami    supported   directl   by
                              splice  occurs,  fastened  with  eight  16d          continuous foundations at the perimeter
                              nails on each side of the splice.                    of the building.
                           5. Gravity  loads  carried  at  the  end  of          2. For  wood  light-frame  construction,
                              cantilevered joists are limited to uniform           floors shall be permitted to be vertically
                              wall  and  roof  loads  and  the  reactions          offset where the floor framing is lapped
                              from  headers  having  a  span  of  8  feet          or tied  together as  required  by Section
                              (2438 mm) or less.                                   R502.6.1.
                    2. Lateral support of roofs and floors. Conditions   6. Perpendicular  shear  wall  and  wall  bracing.
                       where a  section of floor  or roof is not  laterally  Conditions  where  shear  walls  and  braced wall
                       supported by shear walls or braced wall lines on     lines do not occur in two perpendicular directions.
                       all edges.                                        7. Wall bracing in stories containing masonry or
                         Exception: Portions of floors that do not sup-     concrete construction. Conditions where stories
                         port shear walls, braced wall panels above, or     above  grade plane  are  partially  or  completely
                         roofs  shall  be  permitted  to  extend  not  more  braced by wood wall framing in accordance with
                         than 6 feet (1829 mm) beyond a shear wall or       Section R602 or cold-formed steel wall framing
                         braced wall line.                                  in  accordance  with  Section  R603  include
                    3. Shear  wall  or  braced  wall  offsets  in  plane.   masonry  or  concrete  construction.  Where  this
                       Conditions where the end of a braced wall panel      irregularity  applies,  the  entire  story  shall  be
                       occurs  over  an  opening  in  the  wall  below  and  designed in accordance with accepted engineer-
                       extends more than 1 foot (305 mm) horizontally       ing practice.
                       past  the  edge  of  the  opening.  This  provision  is  Exceptions:   Fireplaces   chimneys   and
                       applicable to shear walls and braced wall panels       masonry veneer in accordance with this code.
                       offset in plane and to braced wall panels offset  R301.2.2.7  Height  limitations.  Wood-framed  build-
                       out of plane in accordance with the exception to
                       Item 1.                                         ings shall be limited to three stories above grade plane
                                                                       or the limits given in Table R602.10.3(3). Cold-formed
                         Exception:  For  wood  light-frame  wall  con-  steel-framed buildings shall be limited to less than or
                         struction, one end of a braced wall panel shall  equal to three stories above grade plane in accordance
                         be permitted to extend more than 1 foot (305  with  AISI  S230.  Mezzanines  as  defined  in  Section
                         mm)  over  an  opening  not  more  than  8  feet  R202 that comply with Section R325 shall not be con-