RESOURCE A



                                                        TABLE 3.1—continued
                                          FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
                                                                  PERFORMANCE      REFERENCE NUMBER
                         ASSEMBLY                                                                              REC.
               ITEM CODE                 CONSTRUCTION DETAILS                                           NOTES
                         THICKNESS                                                                            HOURS
                                                                  LOAD   TIME  PRE-BMS-92 BMS-92 POST-BMS-92
                                  6″ deep (3450 psi) concrete deck; 4″ ×
                                  1 / ″ × 5 lbs. R.S.J.; 2′ 6″ C.R.S. with 1″  3 hrs.
                                   3
                                                                                                                1
                                    4
              F/C-6-RC-31   6″    cover on both top and bottom flanges; 12′  25 psf  35 min.      7      1,  2  3 / 2
                                  span simply supported.
                                  6″ deep (4460 psi) concrete deck; 4″ ×
                                  1 / ″ × 5 lbs.  R.S.J.;  2′ C.R.S.; with 1″  4 hrs.
                                   3
                                                                                                                1
                                    4
              F/C-6-RC-32   6″    cover on both top and bottom flanges; 12′  60 psf  30 min.      7      1,  10  4 / 2
                                  span simply supported.
                                  6″ deep (4360 psi) concrete deck; 4″ × 1 / ″
                                                               3
                                                                4
              F/C-6-RC-33   6″    × 5 lbs. R.S.J.; 2′ C.R.S.; with 1″ cover on   60 psf  2 hrs.          7  1, 3  2
                                  both top and  bottom flanges; 13′1″ span
                                  restrained.
                                           3
                                   1
                                  6 / ″ thick; 4 / ″ (5120 psi) concrete core;
                                    4       4
                                                    1
                                  1″ T&G board flooring;  / ″ plaster under-
                                                     2
                            1
              F/C-6-RC-34  6 / ″  coat; 4″ × 3″ × 10 lbs. R.S.J.; 3′ C.R.S.   100 psf 4 hrs.          7  1, 7   4
                             4
                                  flush with top surface concrete; 12′ span
                                  simply supported;  2″ ×  1′3″ clinker con-
                                  crete insert.
                                   3
                                  4 / ″ (3600 psi) concrete core; 1″ T&G
                                    4
                                             1
                                  board flooring;  / ″ plaster undercoat; 4″ ×
                                              2
                                                                                                                1
                            1
              F/C-6-RC-35  6 / ″  3″ × 10 lbs. R.S.J.; 3′ C.R.S.; flush with  100 psf  2 hrs.     7      1,  5  2 /
                             4                                          30 min.                                  2
                                  top surface concrete; 12′ span simply sup-
                                  ported; 2″ × 1′3″ clinker concrete insert.
                                   3
                                  4 / ″ (2800 psi) concrete core; 1″ T&G
                                    4
                                             1
                                  board flooring;  / ″ plaster undercoat; 4″ ×
                                              2
                            1
              F/C-6-RC-36  6 / ″  3″ × 10 lbs. R.S.J.; 3′ C.R.S.; flush with  80 psf  4 hrs.          7  1, 7   4
                             4
                                  top surface concrete; 12″ span simply sup-
                                  ported; 2″ × 1′3″ clinker concrete insert.
                                                       1
                                  (3640  psi) concrete deck;  / ″ reinforce-
                                                        4
                                  ment bars at 6″ pitch with 1 / ″ cover;  / ″
                                                       1
                                                               1
              F/C-7-RC-37   7″                          2       4  169 psf 6 hrs.                 7      1, 14  6
                                  reinforcement bars at 5″ pitch perpendicu-
                                         1
                                  lar with 1 / ″ cover; 13′1″ span restrained.
                                          2
                                  (4060 psi) concrete deck; 4″ × 3″ × 10 lbs.
                                                       1
                                  R.S.J.; 2′  6″ C.R.S. with 1 / ″ cover on
                                                        2
              F/C-7-RC-38   7″    both top and bottom flanges; 4″ × 6″ × 13  175 psf 6 hrs.          7   1, 14  6
                                                       1
                                  SWG mesh reinforcement 1 / ″ from bot-
                                                        2
                                  tom of slab; 13′1″ span restrained.
                                   3
                                  5 / ″ (4010 psi) concrete core; 1″ T&G
                                    4
                                             1
                                  board flooring;  / ″ plaster undercoat; 4″ ×
                                              2
                            1
              F/C-7-RC-39  7 / ″  3″ × 10 lbs. R.S.J.; 2′ 6″ C.R.S.; 1″ down   95 psf  2 hrs.          7  1, 3  2
                             4
                                  from top  surface of concrete; 12′ simply
                                  supported span; 2″ × 1′ 3″ clinker concrete
                                  insert.
                                   3
                                  5 / ″ (3220 psi) concrete core; 1″ T&G
                                    4
                                         1
                                  flooring;  / ″ plaster undercoat; 4″ × 3″ ×
                                          2
                            1
              F/C-7-RC-40  7 / ″  10 lbs. R.S.J.; 2′6″ C.R.S.; 1″ down from   95 psf  4 hrs.          7  1, 7   4
                             4
                                  top  surface of concrete; 12′ simply sup-
                                  ported span;  2″ × 1′3″ clinker concrete
                                  insert.
                                                            (continued)
             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         261
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.