Page 288 - ICC IEBC 2018
P. 288
RESOURCE A
FIGURE 3.3
FLOOR/CEILING ASSEMBLIES—WOOD JOIST
NUMBER OF
ASSEMBLIES
15
The number in each box is
keyed to the last number in the
34 Item Code column in the Table.
For example:
33
32 F/C-W-42
10
31
30
21 38
29 18 37 42
28 16 35 41
5
27 10 20 39
24 8 17 36
26 18 4 13 22
25 9 3 7 15
23 2 1 5 6 11 40 14 12
0
0 1 2 3 4
FIRE RESISTANCE RATING (HOURS)
TABLE 3.3
FLOOR/CEILING ASSEMBLIES—WOOD JOIST
ITEM MEMBRANE PERFORMANCE REFERENCE NUMBER REC.
CODE THICKNESS CONSTRUCTION DETAILS LOAD TIME PRE-BMS-92 BMS-92 POST-BMS-92 NOTES HOURS
12′ clear span - 2″ × 9″ wood joists; 18″ o.c.;
1
2
F/C-W-1 3 / ″ Deck: 1″ T&G; Filler: 3″ of ashes on / ″ boards 60 psf 36 min. 7 1, 2 1 /
8 2
nailed to joist sides 2″ from bottom; 2″ air space;
3
Membrane: / ″ gypsum board.
8
12′ clear span - 2″ × 7″ joists; 15″ o.c.; Deck: 1″
F/C-W-2 1 / ″ 60 psf 22 min. 7 1, 2, 3 1 /
2 1 4
nominal lumber; Membrane: / ″ fiber board.
2
12′ clear span - 2″ × 7″ wood joists; 16″ o.c.;
1
2
F/C-W-3 1 / ″ 2″ × 1 / ″ bridging at center; Deck: 1″ T&G; 30 psf 28 min. 7 1, 3, 1 /
2 1 3
Membrane: / ″ fiber board; 2 coats “distemper” 15
2
paint.
12′ clear span - 2″ × 7″ wood joists; 16″ o.c.; 2″
1
2
F/C-W-4 3 / ″ × 1 / ″ bridging at center span; Deck: 1″ nominal 30 psf 32 min. 7 1, 2 1 /
1
3
16 lumber; Membrane: / ″ fiber board under / ″ 2
16
2
gypsum plaster.
As per previous F/C-W-4 except membrane is
F/C-W-5 5 / ″ 70 psf 48 min. 7 1, 2 3 /
/ ″ lime plaster.
8 5 4
8
As per previous F/C-W-5 except membrane is
F/C-W-6 5 / ″ 70 psf 49 min. 7 1, 2 3 /
/ ″ gypsum plaster on 22 gage / ″ metal lath.
8 5 3 4
8
8
(continued)
2018 INTERNATIONAL EXISTING BUILDING CODE ® 269
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.