Page 288 - ICC IEBC 2018
P. 288

RESOURCE A



                                                            FIGURE 3.3
                                               FLOOR/CEILING ASSEMBLIES—WOOD JOIST

              NUMBER OF
              ASSEMBLIES

                 15
                                             The number in each box is
                                             keyed to the last number in the
                               34            Item Code column in the Table.
                                             For example:
                               33
                               32                      F/C-W-42
                 10
                               31
                               30
                               21  38
                          29   18  37   42
                          28   16  35   41
                  5
                          27   10  20   39
                          24   8   17   36
                      26  18   4   13   22
                      25   9   3    7   15
                      23   2   1    5   6   11   40       14  12
                  0
                    0                     1                      2                     3                      4
                                                  FIRE RESISTANCE RATING (HOURS)



                                                            TABLE 3.3
                                               FLOOR/CEILING ASSEMBLIES—WOOD JOIST
               ITEM   MEMBRANE                                     PERFORMANCE     REFERENCE NUMBER            REC.
               CODE   THICKNESS         CONSTRUCTION DETAILS       LOAD  TIME  PRE-BMS-92 BMS-92 POST-BMS-92  NOTES  HOURS
                               12′ clear span - 2″ × 9″ wood joists; 18″ o.c.;
                                                          1
                                                           2
              F/C-W-1    3 / ″  Deck: 1″ T&G; Filler: 3″ of ashes on  / ″ boards   60 psf 36 min.          7  1, 2  1 /
                          8                                                                                      2
                               nailed to joist sides 2″ from bottom; 2″ air space;
                                        3
                               Membrane:  / ″ gypsum board.
                                         8
                               12′ clear span - 2″ × 7″ joists; 15″ o.c.; Deck: 1″
              F/C-W-2    1 / ″                                     60 psf 22 min.                 7     1, 2, 3  1 /
                          2                         1                                                            4
                               nominal lumber; Membrane:  / ″ fiber board.
                                                     2
                               12′ clear span - 2″ × 7″ wood joists; 16″ o.c.;
                                    1
                                     2
              F/C-W-3    1 / ″  2″ × 1 / ″ bridging at center;  Deck: 1″ T&G;   30 psf 28 min.          7  1, 3,   1 /
                          2             1                                                                        3
                               Membrane:  / ″ fiber board; 2 coats “distemper”                            15
                                         2
                               paint.
                               12′ clear span - 2″ × 7″ wood joists; 16″ o.c.; 2″
                                 1
                                  2
              F/C-W-4   3 / ″  × 1 / ″ bridging at center span; Deck: 1″ nominal   30 psf 32 min.          7  1, 2  1 /
                                              1
                                                               3
                         16    lumber; Membrane:  / ″ fiber board under  / ″                                     2
                                                                16
                                               2
                               gypsum plaster.
                               As per previous F/C-W-4 except membrane is
              F/C-W-5    5 / ″                                     70 psf 48 min.                 7      1, 2   3 /
                               / ″ lime plaster.
                          8    5                                                                                 4
                                8
                               As per previous F/C-W-5 except membrane is
              F/C-W-6    5 / ″                                     70 psf 49 min.                 7      1, 2   3 /
                               / ″ gypsum plaster on 22 gage  / ″ metal lath.
                          8    5                     3                                                           4
                                8
                                                      8
                                                            (continued)
             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         269
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   283   284   285   286   287   288   289   290   291   292   293