Acousti-Seal  911 Technical Data
                                ®
               10 22 26 (10650) Operable Partitions



               ACOUSTI-SEAL  900 SERIES TECHNICAL DATA
                                    ®

                 storage, and operating clearances. Indicate      members fabricated from minimum 16-gage
                 location and installation requirements for       formed steel with overlapped and welded
                 hardware and track, including floor tolerances   corners for rigidity. Top channel is reinforced to
                 required and direction of travel. Indicate blocking   support suspension system components. Frame
                 to be provided by others.                        is designed so that full vertical edges of panels
               C.  Setting Drawings: Show imbedded items and      are of formed steel and provide concealed
                  cutouts required in other work, including support   protection of the edges of the panel skin.
                  beam punching template.                      B. Panel Skin Options:
               D.  Samples: Color samples demonstrating full range      1.  Roll-formed steel wrapping around panel
                  of finishes available by architect. Verification   edge. Panel skins shall be lock formed and
                  samples will be available in same thickness and   welded directly to the frame for unitized
                  material indicated for the work.                  construction. Acoustical ratings of panels with
                                                                    this construction (select one):
               1.5 DELIVERY, STORAGE, AND HANDLING                     a. 50 STC
               A.  Clearly mark packages and panels with               b. 52 STC
                  numbering systems used on Shop Drawings. Do   C.  Hinges for Closure Panels, Pass Doors, and Pocket
                  not use permanent markings on panels.           Doors shall be:
               B.  Protect panels during delivery, storage, and      1.  Full leaf butt hinges, attached directly to panel
                 handling to comply with manufacturer’s direction   frame with welded hinge anchor plates within
                 and as required to prevent damage.                 panel to further support hinge mounting to
                                                                    frame. Hinges mounted into panel edge or
               1.6 WARRANTY                                         vertical astragal are not acceptable.
               A.  Provide written warranty by manufacturer of   D.  Panel Trim: No vertical trim required or allowed on
                  operable partitions agreeing to repair or replace   edges of panels; minimal groove appearance at
                  any components with manufacturing defects.      panel joints.
               B. Warranty period: Two (2) years.              E. Panel Weights:
                                                                  Steel Skin
               PART 2 – PRODUCTS                                     1. 50 STC – 8 lbs./square foot
                                                                     2. 52 STC – 11 lbs./square foot
               2.1 MANUFACTURERS, PRODUCTS, AND OPERATION
               A.  Manufacturers: Subject to compliance with   2.4 PANEL FINISHES
                  requirements, provide products by the following:  A. Panel face finish shall be (select as required):
                  1.  Modernfold, Inc.                            1.  Reinforced vinyl with woven backing weighing
               B.  Products: Subject to compliance with the         not less than 21 ounces (595 g) per lineal yard.
                 requirements, provide the following product:     2.  Reinforced heavy duty vinyl with woven
                  1.  Acousti-Seal  #911 1-Hour UL rated, manually   backing weighing not less than 30 ounces
                               ®
                    operated individual panel operable partition.   (850 g) per lineal yard.
                                                                  3.  Acoustical, non-woven needle punch carpet,
               2.2 OPERATION                                        with fused fibers to prevent unraveling or fray
               A.  Acousti-Seal  #911: Series of individual flat panels,   of material.
                            ®
                  manually operated, top supported with operable      4.  Wall covering and upholstery fabric with
                  floor seals.                                      surface treatment to resist stains.
               B. Final Closure (select one):                     5.  Customer’s own material (subject to factory
                  1.  Horizontally expanding panel edge with        approval), must have UL classification.
                    removable crank.                              6. Full height steel markerboard work surface.
                  2.  Dual horizontally expanding panel edges with      7.  Uncovered for field finishing (subject to field
                    removable crank.                                finish factory approval).
                  3.  Horizontally expanding panel edge with      8. Primed for field finishing.
                    hinged panel closure and removable crank.  B.  Panel trim: Exposed panel trim of one consistent
                                                                 color from manufacturer’s standard offering.
               2.3 PANEL CONSTRUCTION
               A.  Nominal 3-inch (76 mm) thick panels in      2.5 SOUND SEALS
                  manufacturer’s standard 48-inch (1220 mm)    A.  Vertical Interlocking Sound Seals between panels:
                  widths. All panel horizontal and vertical framing   Roll-formed steel astragals, with reversible tongue