Page 138 - Modernfold Architectural Products
P. 138
Acousti-Seal Encore Technical Data
®
®
10 22 26 Operable Partitions
ACOUSTI-SEAL ENCORE SERIES TECHNICAL DATA
®
®
d. Automatic door closer. 3.2 CLEANING AND PROTECTION
e. Self-illuminated exit signs. A. Clean partition surfaces upon completing
B. Work Surfaces: installation of operable partitions to remove
1. Markerboard: White enamel on steel, bonded dust, dirt, adhesives, and other foreign materials
to the face of the panel with horizontal according to manufacturer’s written instructions.
trim without exposed fasteners. Trim is not B. Provide final protection and maintain conditions
acceptable on vertical edges to provide in a manner acceptable to the manufacturer and
uninterrupted work surface. installer that insure operable partitions are without
2. Tackboard: Minimum 1/4-inch (6.35 mm) damage or deterioration at time of Substantial
natural cork, covered with vinyl or fabric, with Completion.
horizontal trim without exposed fasteners. Trim
is not acceptable on vertical edges. 3.3 ADJUSTING
C. Available Accessories/Options: A. Adjust operable partitions to operate smoothly,
1. Pocket Doors: Acousti-Seal Pocket Doors easily, and quietly, free from binding, warp,
®
by Modernfold, Inc., with same finish and excessive deflection, distortion, nonalignment,
appearance as the adjacent panels. misplacement, disruption, or malfunction,
2. Intersecting partition interface. throughout entire operational range. Lubricate
hardware and other moving parts.
PART 3 – EXECUTION
3.4 EXAMINATION
3.1 INSTALLATION A. Examine flooring, structural support, and opening,
A. General: Comply with ASTM E557, operable with Installer present, for compliance with
partition manufacturer’s written installation requirements for installation tolerances and other
instructions, Drawings and approved Shop conditions affecting performance of operable
Drawings. partitions. Proceed with installation only after
B. Install operable partitions and accessories after unsatisfactory conditions have been corrected.
other finishing operations, including painting have
been completed. 3.5 DEMONSTRATION
C. Match operable partitions by installing panels A. Demonstrate proper operation and maintenance
from marked packages in numbered sequence procedures to Owner’s representative.
indicated on Shop Drawings. B. Provide Operation and Maintenance Manual to
D. Broken, cracked, chipped, deformed or Owner’s representative.
unmatched panels are not acceptable.
STC CONSTRUCTION AND TRACK SYSTEM HEIGHT LIMITATIONS
Acousti-Seal Encore ® 52 STC 54 STC 56 STC
®
#17 Bracket Mounted Track 17’-4” (5283 mm) 17’-4” (5283 mm) 15’-4” (4674 mm)
#14 Bracket Mounted Track 24’-4” (7416 mm) 24’-4” (7416 mm) 24’-4” (7416 mm)
#30 Bracket Mounted Track 16’-4” (4978 mm) 12’-4” (3759 mm) 10’-4” (3150 mm)
4 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.