Page 282 - Modernfold Architectural Products
P. 282
ACOUSTI-CLEAR DEMOUNTABLE Technical Data
®
10 22 19 Demountable Partitions
ACOUSTI-CLEAR DEMOUNTABLE SERIES TECHNICAL DATA
®
• Demountable partition system • Floor supported system
• Acoustically rated demountable glass wall system up • Variety of layout configurations available
to 51 STC • Custom glass and RAL powder coating color options
• Flexible office front solution
Modernfold Model
Acousti-Clear Demountable Relocatable, Flat Panels
®
This specification along with product information and model details can be downloaded from www.modernfold.com
SPECIFICATION - SECTION 10 22 19 (10615) DEMOUNTABLE PARTITIONS
PART 1 - GENERAL complete and unedited written test report upon
request.
1.1 RELATED DOCUMENTS C. Single Source Responsibility: Provide glass panel
A. Drawings and general provisions of the partitions and associated hardware by a single
Contract, including General and Supplementary manufacturer through a single source.
Conditions and Division 01 Specification Sections, D. Coordination of Work: Coordinate layout
apply to this Section. and installation of demountable partition
components with other units of Work. Installation
1.2 SUMMARY of ceilings, floor coverings, lighting fixtures, HVAC
A. Section Includes: equipment, and fire-suppression systems should
1. Section includes fixed, framed glass panel be completed before demountable partitions
partitions with swinging glass doors. are installed.
B. Related Sections include the following: E. Coordinate installation of demountable
1. Division 03 Sections for concrete tolerances partition with installation of floor, wall and ceiling
required. construction to comply with substrate tolerance
2. Division 06 Sections for wood framing and requirements of partition manufacturer.
supports, and all blocking at head and jambs F. Do not begin installation until permanent HVAC
as required. systems are properly operating and building and
3. Division 08 Sections for doors, hardware and temperature and humidity have stabilized.
glazing. G. Reference Standards
4. Division 09 Sections for wall and ceiling framing 1. ADA – Americans with Disabilities Act.
at head and jambs. 2. ANSI Z97.1 - Safety Glazing Materials Used in
Buildings.
1.3 QUALITY ASSURANCE 3. ASTM C1036 - Standard Specification for Flat
A. Installer Qualifications: An experienced installer Glass.
who is certified in writing by the demountable 4. ASTM C1048 - Heat-Treated Flat Glass—Kind HS,
partition manufacturer, as qualified to install the Kind FT Coated and Uncoated Glass.
manufacturer’s partition systems for work similar 5. ASTM E84 - Surface Burning Characteristics of
in material, design, and extent to that indicated Building Materials.
for this Project. 6. ASTM E413 - Classification for Rating Sound
B. Acoustical Performance: Test operable partitions Insulation
in an independent acoustical laboratory in 7. CPSC 16 CFR 1201 - Safety Standard for
accordance with ASTM E90 test procedure and Architectural Glazing Materials.
classified in accordance with ASTM E413 to attain 8. NEMA LD3 - High Pressure Decorative
no less than the STC rating specified. Provide a Laminates.