ACOUSTI-CLEAR DEMOUNTABLE Technical Data
                                     ®
               10 22 19 Demountable Partitions




               ACOUSTI-CLEAR  DEMOUNTABLE SERIES TECHNICAL DATA
                                      ®






               •  Demountable partition system                  •  Floor supported system
               •   Acoustically rated demountable glass wall system up   •  Variety of layout configurations available
                 to 51 STC                                      •  Custom glass and RAL powder coating color options
               •  Flexible office front solution




               Modernfold Model
               Acousti-Clear  Demountable                         Relocatable, Flat Panels
                            ®
               This specification along with product information and model details can be downloaded from www.modernfold.com
               SPECIFICATION - SECTION 10 22 19 (10615) DEMOUNTABLE PARTITIONS

               PART 1 - GENERAL                                   complete and unedited written test report upon
                                                                  request.
               1.1 RELATED DOCUMENTS                            C.   Single Source Responsibility: Provide glass panel
               A.   Drawings and general provisions of the        partitions and associated hardware by a single
                  Contract, including General and Supplementary   manufacturer through a single source.
                  Conditions and Division 01 Specification Sections,   D.   Coordination of Work: Coordinate layout
                  apply to this Section.                          and installation of demountable partition
                                                                  components with other units of Work. Installation
               1.2 SUMMARY                                        of ceilings, floor coverings, lighting fixtures, HVAC
               A. Section Includes:                               equipment, and fire-suppression systems should
                  1.  Section includes fixed, framed glass panel   be completed before demountable partitions
                    partitions with swinging glass doors.         are installed.
               B. Related Sections include the following:       E.   Coordinate installation of demountable
                  1.  Division 03 Sections for concrete tolerances   partition with installation of floor, wall and ceiling
                    required.                                     construction to comply with substrate tolerance
                  2.  Division 06 Sections for wood framing and   requirements of partition manufacturer.
                    supports, and all blocking at head and jambs   F.    Do not begin installation until permanent HVAC
                    as required.                                  systems are properly operating and building and
                  3.  Division 08 Sections for doors, hardware and   temperature and humidity have stabilized.
                    glazing.                                    G.  Reference Standards
                  4.  Division 09 Sections for wall and ceiling framing      1. ADA – Americans with Disabilities Act.
                    at head and jambs.                             2.  ANSI Z97.1 - Safety Glazing Materials Used in
                                                                    Buildings.
               1.3 QUALITY ASSURANCE                               3.  ASTM C1036 - Standard Specification for Flat
               A.   Installer Qualifications: An experienced installer   Glass.
                  who is certified in writing by the demountable      4.  ASTM C1048 - Heat-Treated Flat Glass—Kind HS,
                  partition manufacturer, as qualified to install the   Kind FT Coated and Uncoated Glass.
                  manufacturer’s partition systems for work similar      5.  ASTM E84 - Surface Burning Characteristics of
                  in material, design, and extent to that indicated   Building Materials.
                  for this Project.                                6.  ASTM E413 - Classification for Rating Sound
               B.   Acoustical Performance: Test operable partitions   Insulation
                  in an independent acoustical laboratory in       7.  CPSC 16 CFR 1201 - Safety Standard for
                  accordance with ASTM E90 test procedure and       Architectural Glazing Materials.
                  classified in accordance with ASTM E413 to attain      8.  NEMA LD3 - High Pressure Decorative
                  no less than the STC rating specified. Provide a   Laminates.