Page 358 - Modernfold Architectural Products
P. 358
Modernfold GWS SR-DRS/TR-DRS Technical Data
10 22 26 (10650) Operable Partitions
MOVABLE GLASS WALL TECHNICAL DATA
PANEL DETAILS – STACKING CONFIGURATIONS
Intermediate Panel Closure
Pivot Panel Closure 90º Side Stack 90º Side Stack (Remote)
STACK DEPTH
+ 11" (279 mm)
WELDMENT MIN.
DEPTH
WIDEST PANEL WIDTH +2" (51 mm) MINIMUM WELDMENT DEPTH = WIDEST PANEL WIDTH +5" (127 mm) MINIMUM
STACK DEPTH
+ 6" (152 mm)
7" (178) MIN. 10" (254) MIN.
STACK Model Detail from Model Detail from
DEPTH Website STACK Website
NO. OF PANELS × 2.75" (70 mm) +2” (51 mm) DEPTH
GW-500 NO. OF PANELS GW-501
× 2.75" (70 mm) + 2" (51 mm)
Intermediate Panel Closure Intermediate Panel Closure
Parallel Side Stack (Remote) 135º Side Stack (Remote)
2'-0" (610 mm) MIN.
2'-0" (610 mm) MIN
SIDE "R"
1'-0" (305) SIDE "L"
1'-0" (305 mm) HOLD
STACK DEPTH*
STACK DEPTH*
*STACK DEPTH *STACK DEPTH WIDEST PANEL
NO. OF PANELS
7"
NO. OF PANELS × 2.75" (70 mm) (178 mm) WIDTH + 6"
7"
× 2.75" (70 mm) (178 mm) WIDEST PANEL + 2" (51 mm) MIN. (152 mm) MIN.
WIDTH + 2"
+ 2" (51 mm)
HOLD (51 mm) MIN
Model Detail from Model Detail from
Website Website
GW-502 GW-503
10 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.