Page 37 - Modernfold Architectural Products
P. 37

ACOUSTI-SEAL  ENCORE
                                                   ®
                                                                               ®
       ACHIEVING OPTIMAL ACOUSTICS




       Acousti-Seal  Encore  movable walls have been laboratory tested to an industry
                     ®
                               ®
       leading 56 STC... How does that translate into an actual space?


       STC or Sound Transmission Class is   acoustical control within each space.   often be eliminated or diminished by
       a two-digit number describing the   The guidelines for duplicating the   installing baffling, sound barriers, or sound
       acoustical control of a partition in a   sound lab environment within an actual   -absorbing insulation in key areas.
       sound laboratory setting. This method   space are detailed in the ASTM E557
       of ranking is the most widely accepted   specification.              Above the Partition Track
       standard throughout the industry.
       Virtually every operable partition   ASTM E557 is the blueprint for the
       manufacturer conducts laboratory   successful construction surrounding
       tests and must be able to validate their   acoustically rated operable partitions.
       products results.                  The ASTM E557 specification can be
                                          purchased online at www.ASTM.org
       To be certified as a sound laboratory, a   and is an absolutely essential guide for
       lab must be constructed to meet strict   your spaces overall acoustical success.
       ASTM specifications and be certified by   The STC of your operable partition is   A plenum above a partition can allow
       a third party. A quality sound laboratory   basically irrelevant if the surrounding   sound to pass up through the ceiling on
       has the ability to take everything out of   construction is not up to the ASTM E557   one side and down to the other side. To
       the surrounding environment except for   specification. You will lose the intended   eliminate this problem, a barrier (with
       the partition that is being tested.   acoustical control of the operable   a sound transmission loss equal to or
                                          partitions through the surrounding   greater than the partition) should be
       Therefore, an STC rating calculates   construction and unrecognized   created above the partition.
       only the partition itself without any of   construction errors.
       the surrounding construction. This is                                Partition-to-Wall Connections
       very important to understand because   The following are the most common
       when a partition is placed into an actual   construction errors in regards to
       building, that building will not be built   successful acoustical control and
       to the same standards as the sound   operable partitions:
       laboratory and therefore will affect the
       acoustical performance within the space.  Flanking Paths

       When you consider that an operable
       wall may represent only 10% of the                                   Operable partitions use various methods
       surface area in a space, you quickly                                 to connect with permanent walls and
       realize it takes more than just a great                              partitions. These include fixed jambs
       operable wall to achieve optimal                                     mounted to the partition or permanent wall,
       acoustical control within the space.                                 recessed jambs on the permanent surface,
       Acoustical success takes a great                                     and multi-point bulb seals. Whatever the
       acoustical plan for the surrounding   Airborne sound can be transmitted to   case, provisions should be made to allow
       construction by the Acoustician,                                     for air tight closure against the permanent
       Architect, and General Contractor. One   adjoining rooms by way of adjacent   wall without interference from chair rails,
                                          doors, door grilles, air handling ducts,
       must understand that it is not realistic   ceiling plenums, or floors and walls   crown moldings, or other surface materials.
       to duplicate the sound lab environment   passing beneath the partition or from
       in an actual space, but duplicating the   room-to-room at the ends of the   For more detailed acoustic information
       environment as closely as possible                                   please reference Modernfold’s Acoustical
       will determine the overall quality of the   partitions. These flanking paths can   Guide Form 2503.