               08 35 13 Accordion Folding Doors


               Soundmaster  & Modernfold  TECHNICAL DATA
                                  ®
                                                        ®


               This specification along with product information and model details can be downloaded from www.modernfold.com
               SPECIFICATION - SECTION 08 35 13 ACCORDION FOLDING DOORS

               PART 1 - GENERAL                                   and accessories. Indicate dimensions, weights,
                                                                  conditions at openings, and at storage areas,
               1.1 RELATED DOCUMENTS                              and required installation, storage, and operating
               A.  Drawings and general provisions of the Contract   clearances. Indicate location and installation
                  including General and Supplementary Conditions   requirements for hardware and track, including
                  and Division 01 Specification Sections, apply to   floor tolerances required and direction of travel.
                  this Section.                                   Indicate blocking to be provided by others.
                                                                C.  Setting Drawings: Show imbedded items and
               1.2 SUMMARY                                        cutouts required in other work, including support
               A. This Section includes the following:            beam punching template.
                  1.  Furnish and install accordion folding partitions   D.  Samples: Color samples demonstrating full range
                    as indicated in drawings.                     of finishes available by architect. Verification
               B. Related Sections include the following:         samples will be available in same thickness and
                  1.  Division 03 Sections for concrete tolerances   material indicated for the work.
                    required.
                  2.  Division 05 Sections for primary structural   1.5 DELIVERY, STORAGE, AND HANDLING
                    support, including pre-punching of support   A.  Clearly mark packages and partitions with
                    members by structural steel supplier per      numbering systems used on Shop Drawings. Do
                    partition supplier’s template.                not use permanent markings on partitions.
                  3.  Division 06 Sections for wood framing and   B.  Protect partitions during delivery, storage, and
                    supports, and all blocking at head and jambs   handling to comply with manufacturer’s direction
                    as required.                                  and as required to prevent damage.
                  4.  Division 09 Sections for wall and ceiling framing
                    at head and jambs.                          1.6 WARRANTY
                                                                A.  Provide written warranty by manufacturer of
               1.3 QUALITY ASSURANCE                              partitions agreeing to repair or replace any
               A.  Installer Qualifications: An experienced installer   components with manufacturing defects.
                  who is certified in writing by the partition   B. Warranty period: Two (2) years.
                  manufacturer, as qualified to install the
                  manufacturer’s partition systems for work similar in   PART 2 – PRODUCTS (SOUNDMASTER)
                  material, design, and extent to that indicated for
                  this Project.                                 2.1 MANUFACTURERS, PRODUCTS, AND OPERATION
               B.  Preparation of the opening shall conform to   A.  Manufacturers: Subject to compliance with
                 the dimensions specified, plumb, level, and in   requirements, provide product by the following:
                 accordance to building practices.                 1. Modernfold, Inc.
               C.  Acoustical Performance: Test partitions in   B.  Products: Subject to compliance with the
                  an independent acoustical laboratory in         requirements, provide the following product:
                  accordance with ASTM E90 to attain no less than      1. Soundmaster #8 Accordion Folding Partition.
                  the STC rating specified. Provide a complete      2. Soundmaster #12 Accordion Folding Partition.
                  and unedited written test report by the testing
                  laboratory upon request.                      2.2 OPERATION
                                                                A.  Soundmaster #8: Manually operated, top
               1.4 SUBMITTALS                                     supported, accordion folding.
               A.  Product Data: Material descriptions, construction   B.  Soundmaster #12: Manually operated, top
                  details, finishes, installation details, and    supported, accordion folding.
                  operating instructions for each type of partition,
                  component, and accessory specified.           2.3 CONSTRUCTION
               B.  Shop Drawings: Show location and extent of   A.  Shall consist of steel hinge plates welded to
                 partitions. Include plans, elevations, sections,   3/16-inch (5mm) diameter vertical steel rods,
                 details, attachments to other construction,      with a single row of plates at the bottom and top