Darley:


               Output at 700 kPa           3600 l/m
               Output at 1000 kPa          2700 l/m
               Max. Main Pressure          1700 kPa
               Hose Reel Pressure          3500 kPa
               Hose Reel Flow              360 l/m

              At the start of every shift the pump
              operator should check the preset relief
              valves are set at 1000 kPa
              Hale:


               Output at 1000 kPa          3800 l/m
               Max. Main Pressure          1600 kPa
               Hose Reel Pressure          3000 kPa
               Hose Reel Flow                    360 l/m



              DO NOT preset Hale relief valves. They
              sustain damage when they are left
              under tension for too long.