Page 28 - Pricelist
P. 28
FLUORESCENCE SPECTROSCOPY MODEL QUO
Fluorescence analysis is a highly selective and sensitive sophisticated analytical method. This method can
provide information including excitation and emission spectrum, emission light intensity, measurement of
life of emission light and polarization fluorescence etc. Fluorescence Spectroscopy is becoming an important
analytical method in the region of trace analysis. BioEra’s Fluorescence Spectroscopy Model Quo fulfills
complete basic requirements of fluorometry analysis.
CAT. NO.: BE/CI/SP/FSQ-01
PRICE / UNIT: ` 5,85,000/-
FEATURES
• Dual Operation Mode: Fluorescence Intensity and power source ensure high stable testing and wide
Luminous Intensity. range of spectrum.
• Fluorescence Intensity Mode offers fluorescence • The normalized feature for fluorescence value can
scanning, kinetic determination and quantity make different fluorescence's result comparable.
analysis. • Provision of qualitative and quantitative software
• 365nm exciting wavelength Raman peak of water in package offers expansible time scanning,
1 cm quartz fluorescence cuvette S/N≥150 wavelength scanning, graphic calculation and
• High performance sensitivity makes analysis storage-access.
possible for even the lower detective samples. • Provision of Exciting optical filters and Interference
• Provision of 10 stages gain adjustment selection for optical filter.
emission spectrum scanning, including high speed • Standard set is equipped with an interference
low S/N scanning and precise scanning. optical filter of central wavelength at 365nm and
• Total spectrum scanning could be completed in just 10nm bandwidth.
1 second. • An optional interference optical filer of 25mm
• Provision of intelligent pre scanning feature assists diameter of wavelength of 200-850 nm can be
in rapid detection of unknown sample's spectrum. provided on users demand.
• Auto-emission of the influence of scattering • Emission monochromator is C-T diffraction grating
peak and harmonic peaks ensures the better (Em 200~900nm, bandwidth 10nm).
measurement parameters to locate the • Wavelength accuracy is ±1nm
fluorescence emission peak. • Wavelength repeatability is ≤0.5nm
• Support off-line mode and on-line mode of • Linear measurement(r): ≥0.995
working. Under off-line mode, instrument's • Stability: better than 1.5%/10min
computer system offer the fluorescence intensity
measurement, concentration direct reading, auto • Variation of power source: 220V±22V ; 50Hz±1Hz
0 adjustment, auto background subtraction etc. • Response time: (0.1-4)s ; 6 stages adjustable
Under on-line mode, use of quality and quantity • Fluorescence display value: 0.00-600.00
software can be done to for data acquisition and • Data transmission: USB2.0
analysis through USB2.0 interface. • Dimension (WXDXH): 380×445×310 mm
• High stable and long life 150W Xenon Lamp and • Net Weight: 13kg
28 BioEra Life Sciences Pvt. Ltd. | www.bioera.in