Page 11 - 01
P. 11
Textbook (Source) : Membrane Technology and applications (Richard W. Baker, John Wiley & Sons, 2 nd Ed)
Membrane Processes
4
N
d 2
where ε is the porosity
Flux (flow per unit membrane area)
p
J d 2
32 l
J 2
d
p 32 l
• Flux per unit pressure difference of MF membrane is enormously
higher than that of RO membrane !