               single-lumen endotracheal tube (ET) with intraluminal or extraluminal ballooned catheter such
               as Univent, Arndt, Cohen, or EZ-blocker although they tend to deflate the isolated lung slowly.
               Fiberoptic bronchoscopy is often used to facilitate the bronchial blocker placement and adjust
               position when dislodged or misaligned.

                   In summary, DLTs were introduced from early animal and human physiology experiments
               and have evolved into clinical practice (Table 1). These developments will continue with new
               technology and material in the modern era with real-time visualization, built-in suctioning
               capacity, easily converting to single-lumen tube, and minimized airway trauma.




               References


               1. F. Trendelenburg. Beitrage zu den operationen au den Luftwegen. Arch Klin Chir (1871)12: 321-361
               2. W. Macewen. Clinical Observations on the Introduction of Tracheal Tubes by the Mouth, Instead of Performing
               Tracheotomy or Laryngotomy. Br Med J. (1880) 2(1022):163-5.
               3. F. Kuhn. Der Metallschlauch in der Tubage und als Trachealkancile. Wien. klin. Rdsch (1900) 28: 554
               4.  F. Kuhn. Die perorale Intubation. Zentralbl. Chir (1901)28: 1281-1285
               5. S. Wolffberg. Ueber die spannung der Blutgase in die Lungen. Pflügers Arch (1871) 4: 465-492
               6. H. Head. On the regulation of respiration theoretical and experimental. J Physiol (1889)10 (1): 279-290
               7. A. Loewy, H. von Schrotter. Untersuchungen uber die Blutcirculation beim Menschen. Z Exp Pathol (1905)
               1:197-310
               8. H. Jacobaeus, P. Frenckner, S. Bjorkman. Some attempts at determining the volume and function of each lung
               separately. Ada Med (Scand) (1932) 79:174-215.
               9. W. Zavod. Bronchospirometry: description of catheter and technique of intubation. J Thorac Surg (1940) 10:27-
               31
               10. E. Carlens. A new flexible double lumen catheter for bronchospirometry. J Thorac Surg, (1949)18:742-746
               11. R.A. Green, W.Gordon. A new right endobronchial tube. Lancet (1955) 1:185.
               12. R.A. Green, W.Gordon. Right lung anaesthesia: anaesthesia for left lung surgery using a new right
               endobronchial tube. Anaesthesia (1957)12: 86
               13. G.M.J. White. Evolution of endotracheal and endobronchial intubation. Br J Anaesth (1960) 32:235-246
               14. G.M.J. White. Two-way union for double lumen tubes. Anaesthesia (1960) 15:77-79
               15. R. H. Salt. A modified two-way union for double lumen tube. Anaesthesia (1970)25(3):418-419
               16. R. Bryce-Smith, R. Salt. A right sided double lumen tube. Br J Anaesth (1960) 32: 230-231
               17. F.L. Robertshaw. Low resistance double-lumen endobronchial tubes. Br J Anaesth (1962) 34:576-579
               18. J.L. Benumof. Improving the design and function of double-lumen tubes. J Cardiothorac Anesth   1988; 2:729–
               33
               19. S. Hagihira, M. Takashina, T. Mashimo. Application of a newly designed right-sided, double-lumen
               endobronchial tube in patients with a very short right mainstem bronchus. Anesthesiology (2008) 109:565–568.
               20. J. Lohser, J.b. Brodsky. Silbronco Double-Lumen Tube. JCVA volume 20 issue 1, December 30, 2005. p129-
               131
               21. S. Ghosh, F.Falter, K.Goldsmith. The Papworth BiVent tube: a new device for lung isolation. Anaesthesia.
               (2008) 63:996–17000
               22.S. Ghosh, A.A. Klein, M. Prabhu. The Papworth BiVent tube: a feasibility study of a novel double-lumen
               endotracheal tube and bronchial blocker in human cadavers. Br J Anaesth. (2008)101: 424–428
               23. M. Barak M, V. Putilov, S. Meretyk, S. Halachmi. ETView tracheoscopic ventilation tube for surveillance after
               tube position in patients undergoing percutaneous nephrolithotomy. Br J Anaesth. 2010 Apr;104(4):501-504