Page 107 - Fundamental Of Design In Mechanical Engineering
P. 107

Example 1


     ◦ A shaft  50mm in diameter is carrying 370kW at 3600 rpm. A 12-mm square

        key transmit the power to the hub. If the allowable compressive stress is 250
        Mpa, what is the minimum length of a key required to support the

        compressive load?

                                                                                                          ANSWER  L= 26mm











        Example 2



     ◦ A shaft 50mm in diameter is carrying 370kW at 3600 rpm. A 12-mm square
        key transmit the power to the hub. If the allowable shearing stress is 350

        MPa, how long should the key be based on the shearing stress?




                                                                                                         ANSWER  L= 9.3mm








                                                                                                                                    107