P. 2
ATEX safety is standard
Product’s features Areas of use
Type Category Type of Classe de temperature CE type examination G-GAS D-DUST
II 2 G protection Gas Dust certificate 012 20 21 22
MVSI-E II 2 D
M3-E** Ex e IIC Gb T3 from 120° LCIE 06
MTF-E II 2 D Ex tb IIIC Db (200° C) to 200° C* ATEX 6092 X
VB-E II 2 D T4
MVB-E (135° C)
MVB-E-FLC
tD A21 IP66 - from 120° LCIE 05
MVSI tD A21 IP66 - to 200° C* ATEX 6163 X
M3 tD A21 IP66 -
tD A21 IP66 - from 120° LCIE 05
MVSI-TS to 170° C* ATEX 6163 X
MTF II 2 D from 120° C LCIE 05
to 150° C* ATEX 6163 X
VB II 2 D from 135° C LCIE 05
MVB*** II 2 D to 150° C* ATEX 6163 X
MVB-FLC***
IP66 - 120° C LCIE 03
MVSS-P 120° C ATEX 6005 X
-
CDX II 2 G Ex d IIB Gb 120° C - DEMKO 07
II 2 D Ex tb IIIC Db ATEX 0612032X
CDX II 2 G
gr.110 Ex d IIB T4 SIRA 00
CDX-G II 2 G Ex d IIB Gb (135° C) ATEX 1026
160° C DEMKO 07
ATEX 0612032X
MVTX II 2 G Ex d IIB Gb T105° C 105° C DEMKO 07
II 2 D ATEX 1103487X
Ex tb IIIC Db
MVTX-G II 2 G Ex d IIB T150° C - DEMKO 07
ATEX 1103487X
** Only T4 * According to model (See the specific tables in the catalog). Compatible
*** Only model gr. 50 Incompatible
How to choose the right Italvibras electric vibrator
To establish which type of electric vibrator Zone The choice of the electric vibrator on the basis of area
is best for the specific use required, the
environment in which the electric vibrator Products suitable for the area
is to work must be classified by defining
the area, the maximum temperature and, if 1, 2, 21, 22 - Ex e MVSI-E, M3-E, MTF-E, VB-E, MVB-E, MVB-E-FLC
necessary, the required type of protection.
The EN specifications (e.g. EN 60079-10) 21, 22 MVSI, M3, MVSI-TS, MTF, VB, MVB, MVB-FLC, MVSS-P
can be used to conduct these analyses.
Once the area has been classified, the ta- 1, 2, 21, 22 - Ex d CDX, MVTX N
bles alongside will allow you to identify the 1, 2 - Ex d
most suitable Italvibras electric vibrator. CDX-G, CDX gr.110, MVTX-G
The technical staff at Italvibras is always at
the customers’ complete disposal for any Production quality assurance notification.
further explanations that may be required. Directive 94/9/CE n° CESI 00 ATEX 061 Q.
B
2
H