Page 33 - ITALVIBRAS E-CATALOG
P. 33
Fig. A D ØG N Fig. CN
L M
A B
I H
F
E
C
Dimensional specifications (mm)
Max. current Holes Cable entry
A thread
tE (s) IA/lN Type Fig. A B C D E øG N° F H I L M N
400 V 460 V 25 2.00 MVSI 075/150E-S02
50 Hz 60 Hz
0.67 0.64 A 344 203 167 105 140 13 4 30 82.5 93 145 140 160 M25x1,5
0.86 0.80 25 2.47 MVSI 075/250E-S02 A 394 216 205 120 170 17 4 45 93.5 106 170 160 182 M25x1,5
0.57 0.56 30 1.66 MVSI 075/400E-S02 A 435 225 205 120 170 17 4 54 104.5 117.5 187 162 203 M25x1,5
1.14 1.10 30 2.15 MVSI 075/660E-S02 A 500 246 230 140 190 17 4 54 116 134 207 190 225 M25x1,5
MVSI 075/910E-S02 A 574 246 230 140 190 17 4 54 116 171 207 190 225 M25x1,5
1.33 1.30 30 2.14 MVSI 075/1310E-S02 A 617 272 275 155 225 22 4 70 130 177 238 210 253 M25x1,5
1.14 1.10 25 2.50
2.09 2.10 30 2.63
3.61 3.60 15 4.18 MVSI 075/2110E-S02 A 666 321 310 155 255 23.5 4 77 157 178 277 215 295 M25x1,5
5.13 5.00 13 3.96 MVSI 075/3110E-S02 A 734 347 340 180 280 26 4 80 165 202 303 240 320 M32x1,5
5.70 6.00 14 4.00 MVSI 075/3800E-S02 A 796 347 340 180 280 26 4 80 165 233 303 240 320 M32x1,5
6.18 6.20 14 3.84 MVSI 075/4200E-S02 A 744 370 390 200 320 28 4 90 180 192 330 270 350 M32x1,5
7.79 7.40 14 3.80 MVSI 075/5300E-S02 A 840 370 390 200 320 28 4 90 180 240 330 270 350 M32x1,5
11.4 11.0 17 3.50 MVSI 075/10000E-S02 C 1002 437 460 125 380 39 6 35 215 300 387 320 414 M32x1,5
tE (s) = set time tE from IEC/EN 60079-7. IA/lN = ratio between start-up current and maximum current.
Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras.
33