Page 42 - ITALVIBRAS E-CATALOG
P. 42

CDX

                                                                                                The CDX explosion-proof vibrators
                                                                                                have been designed for use in indu-
                                                                                                strial processes in a potentially explosi-
                                                                                                ve atmosphere.
                                                                                                The enclosure of the CDX vibrators is
                                                                                                equipped with increased thickness and
                                                                                                joints to prevent the transmission of an
                                                                                                internal explosion to the surrounding
                                                                                                area.
                                                                                                The CDX series is characterized and
                                                                                                enhanced by many different certifi-
                                                                                                cations, depending on the vibrator
                                                                                                model.

Technical features

Power supply                                    Protection against mechanical impacts           is constructed to contain internal explo-
Three-phase voltage from 24V to 690V            IK 08 according to IEC 68, EN 50102.            sions. Special shaped terminals allow to
(limit at 600V for UL and CSA certifications),                                                  fix the power supply cable, protecting it
50Hz or 60Hz, or single-phase 100-130V          Insulation class                                from loosening.	
60Hz and 200-240V 50Hz; suitable for use        Class F (155°C).
with a PWM inverter from 20Hz to the                                                            Electric motor
base frequency with constant torque load        Tropicalization                                 Three-phase and single-phase asyn-
profile.                                        Standard on all vibrators, with vacuum          chronous type. Designed for maximum
	                                               encapsulation up to size 35, with “drop         starting torques and torque curves
Polarity                                        by drop” trickle system for larger sizes.       specific to requirements of the vibrating
2, 4, 6 and 8 poles.                                                                            machines. Insulated windings using vacu-
                                                Ambient temperature                             um encapsulating up to size 35; using the
Reference Regulations and Directives            From -20°C to +40°C.	                           “drop by drop” trickle system with Class H
See table below.                                                                                resin for the larger sizes. The rotor is die
                                                Vibrator thermal protection                     cast aluminium.
Controls                                        With thermal protector at 130°C for the
The components that affect protection           entire CDX range, or on request with PTC        Casing
are 100% accurately controlled and              thermistors rated heat detectors 130°C          In high-tensile aluminium alloy up to size
recorded.                                       (DIN 44081-44082).	                             30, in spheroidal cast iron for larger sizes.
                                                                                                Patented shape that improves heat
Functioning                                     Fixing of the vibrator                          dispersion and lowers normal running
Continual service (S1) at maximum decla-        In all positions and therefore without          temperature with full load.
red centrifugal force and electric power.       restriction.                                    An external earthing screw is located on
Intermittent services are also possible                                                         the casing as prescribed by Regulation
depending on the type of vibrator and the       Lubrication                                     IEC/EN 60079-0.	
operating conditions. For detailed infor-       All vibrators are lubricated in the factory
mation, contact our technical assistance        and do not require further lubrication          Bearing flange
office.                                         if used in normal operating conditions          Constructed in spheroidal or grey cast
                                                (“FOR LIFE” lubrication). In heavy duty         iron.
Centrifugal force                               operating conditions periodical re-             The geometry of the flange transmits the
Range extended to 22400 Kgf. (220 KN),          lubrication may be applied to size 40 and       load to the casing uniformly.	
with centrifugal force adjustable from 0        larger.
to 100%.                                        		                                              Bearings
                                                Terminal box
Mechanical protection                           Large fixed electrical connections. The         Custom made with particular geome-
Mechanical protection IP66 according to         terminal cover, with increased thickness,
IEC 529, EN 60529.                                                                           N  try, especially designed for Italvibras,
                                                                                                suitable to support both high radial and

                                                                                                axial loads.

                                                                                                	

                                                                                                                                     B

42

                                                                                                                               H