Page 72 - ITALVIBRAS E-CATALOG
P. 72

MVB-E/MVB-E-FLC

                                                                                                 The MVB-E and MVB-E-FLC flanged vibrator series have
                                                                                                 been designed for use in industrial processes with screens
                                                                                                 and sieves in environments with a potentially explosive
                                                                                                 atmosphere, caused by gas and dusts, in compliance with
                                                                                                 ATEX Directive (94/9/EC).
                                                                                                 These vibrators can be supplied in B, C, D versions (see
                                                                                                 page 70) according to the eccentric weights supplied with
                                                                                                 the vibrator and to be mounted by the user.
                                                                                                 In particular, these vibrators can be used in areas 1 and 2
                                                                                                 (gas) and in areas 21 and 22 (dusts) according to the layout
                                                                                                 and the following features:

Technical features

Power supply                                 Protection against mechanical impacts         Terminal box
Three-phase voltage from 220V to 690V,       IK 08 according to IEC 68, EN 50102.          Large fixed electrical connections.
50Hz or 60Hz; suitable for use with a                                                      Special shaped terminals allow to fix the
PWM inverter from 20Hz to the base fre-      Insulation class                              power supply cable, protecting it from
quency with constant torque load profile.    Class F (155°C).                              loosening.

Polarity                                     Tropicalization                               Electric motor
4 poles.                                     Standard with “drop by drop” trickle system.  Three-phase asynchronous type. Insula-
                                                                                           ted windings using “drop by drop” trickle
Conformity with European Directives          Ambient temperature                           system with class H resin.
Low Voltage 2006/95/EC,                      From -20°C to +40°C, on request it is pos-    The rotor is die cast aluminium.
ATEX 94/9/EC.                                sible to have vibrators for max. ambient
                                             temperature +55°C.                            Casing
Reference Regulations                                                                      In spheroidal cast iron to have high
IEC/EN 60079-0, IEC/EN 60079-7,              Vibrator thermal protection                   strength and optimal elasticity.
IEC/EN 60079-31, EN 60034-1.                 On demand with PTC rated thermistor heat      An external earthing screw is located on
                                             detectors 130°C (DIN 44081-44082). Also on    the casing as prescribed by Regulation
Controls                                     request thermistors with different tempe-     IEC/EN 60079-0.
The components that affect protection are    ratures and anti-condensation heaters.
100% accurately controlled and recorded.                                                   Bearing flange
                                             Fixing of the vibrator                        Constructed in spheroidal cast iron.
Functioning                                  In all positions and therefore without        The geometry of the flange transmits the
Continual service (S1) at maximum decla-     restriction.                                  load to the casing uniformly.
red centrifugal force and electric power.
                                             Lubrication                                      Bearings
Centrifugal force                            All vibrators are lubricated in the factory      Custom made with particular geome-
1500 Kgf. (14.7 KN), adjustable with varia-  and do not require further lubrication           try, especially designed for Italvibras,
tion of the eccentric weights.               if used in normal operating conditions           suitable to support both high radial and
                                             (“FOR LIFE” lubrication). In heavy duty          axial loads.
Mechanical protection                        operating conditions periodical re-lubri-
IP 66 according to IEC 529, EN 60529.        cation may be applied.                        N

                                                                                                                                     B

72

                                                                                                                               H